20.11.2012 Views

Competence.Work Parquet - 1926 Wood Flooring

Competence.Work Parquet - 1926 Wood Flooring

Competence.Work Parquet - 1926 Wood Flooring

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

7<br />

PARKETT-HANDBUCH<br />

8. THE INSTALLATION OF BAUWERK PARQUET<br />

• Exotic woods in particular reveal a considerable interplay of colours when<br />

new. As a result of natural processes (e.g. aging and oxidation), however,<br />

this wide range of colours narrows down in the course of time, i.e. the<br />

wood darkens and the colour contrasts diminish.<br />

• In order to avoid a heavy soiling of the parquet it is essential to install<br />

entrance carpets for dirt and floor covering to walk over.<br />

• We recommend the application of felt pads under all chairs and table legs,<br />

and castor cups underneath roller castors in order to avoid any scratching of<br />

the surface.<br />

• The installation of a transparent plastic mat where office chairs are used can<br />

help avoiding local abrasion.<br />

8.2. Laying instructions for Maxipark Active Floor (sport flooring)<br />

Product description<br />

There is a complete laying instruction manual in every second packet. Also,<br />

we strongly recommend working with Bauwerk laying tools.<br />

Preparation<br />

– Make sure you have installed a vapour barrier if necessary.<br />

– Calculate how many planks fit into the room’s width. If the last row<br />

of planks is narrower than 30mm, the first row should also be cut<br />

lengthwise. Installing parquet with <strong>Wood</strong>loc-joints is best begun at the<br />

room’s longitudinal side with the most doors. Should one of the short<br />

sides of the room have the most doors, it is better to begin each row of<br />

planks at that wall. The planks can be laid from left to right and also the<br />

other way around.<br />

– Maximum floor width: 18 meters. If the floor is wider than this, please<br />

consult Bauwerk.<br />

Installation<br />

1. Begin in a corner from left to right with the long tongue facing the wall.<br />

The lengthwise distance to the wall can still be changed later, once the<br />

first three rows have been laid. An additional elastic module has to be<br />

laid beneath the first row at the wall side of the planks. This will prevent<br />

the planks from breaking through to the subfloor. The same has to be<br />

done to the last row as well.<br />

2. Press the next plank against the first one at a shallow angle and lay<br />

it down. Continue laying the entire first row in this manner. Use a guide<br />

string to make sure that the first planks have been laid correctly.<br />

. Saw the last plank of the first row to the correct length. Begin the next<br />

row with the left-over piece form the first row. Stagger the short ends of<br />

the planks by at least 50cm.<br />

. Press then next plank against the previous row at a shallow angle.<br />

Carefully tap it into position using the tapping block while laying it down.<br />

5. Slide the laying wedge under the short end of the already laid plank.<br />

6. Place the new plank’s end face at an angle to the previously laid planks<br />

and lay it flat.<br />

7. Remove the wedge. Hammer the planks carefully with the tapping block<br />

into the longitudinal profile until the gap is closed.<br />

8. Sometimes the first row has to be adjusted to bent walls. This is done by<br />

drawing the equivalent angle to the first planks. Carefully saw the planks<br />

to the matching width.<br />

9. Holes must be drilled for heating pipes. These holes have to be at<br />

least double as wide as the calculated expansion gap to the wall plus the<br />

diameter of the pipe. For example: is the floor 10m in width, the<br />

hole must be double the size of the expansion gap (which is 10 x 1.5mm =<br />

15mm) plus the diameter of the pipe, hence 2 x 15mm = 30 mm<br />

wider than the pipe. Cut out the piece as shown in the picture. When the<br />

planks are assembled, glue on the cut-off piece and cover the hole<br />

with pipe collar.<br />

10. The last row of planks is cut lengthwise to the right size. To do so, place<br />

these planks over the plank of the second last row including a 5 mm