LNC MILLMACRO Program5.5.2 Classification of Open System Variables1. MLC I/O Interface Signals• OP MLCMLC C Bit C100~C115$200~$215• OP MLCMLC S Bit S100~S115$600~$6152. Date and Time Information• $190 = Axis interruption accumulation count: Whenever the motion card delivers aninterruption signal, this value will be added by one.• $191~$193 = System Date: Read from IPC BIOS$191 = Year, yyyy$192 = Month, mm$193 = Day, dde.g.: 2002/08/15 $191=2002$192=8$193=5• $194~$196 = System Time: Read from IPC BIOS$194 = 24hr, hh$195 = minute, nn$196 = second, sse.g.: 14:25:34 $194=1$195=25$196=34230 LNC Technology Co., Ltd.