12.07.2015 Views

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Modified Bitumen Part 3: Modified Bitumen SpecificationsTYPE OF ROOFINSTALLATION &SUBSTRATEMANUFACTURER'SSPECIFICATION NO.TOTALNUMBER OFPLIES INMEMBRANEASSEMBLYBASE SHEETDESCRIPTIONIF OTHER THANMODIFIEDBITUMEN SHEETNAME(S) OF MODIFIED BITUMEN SHEET(S) USED IN MEMBRANEFIRST SHEET SECOND SHEET THIRD SHEETGTAFR-N-B3 3 - FLEXIGLAS BASE FLINTLASTIC STA FLINTLASTIC GTA-FRGTAFR-N-B4 4 - FLEXIGLAS BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC GTA-FRGMS-N-B2 2 GLASBASE - FLINTLASTIC GMS -GMS-N-B3 3 - FLEXIGLAS BASE FLINTGLAS PLY IV FLINTLASTIC GMSGMS-N-B4 4 - FLEXIGLAS BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC GMSFRP-N-B2 2 GLASBASE - FLINTLASTIC FR-P -FRP-N-B3 3 - FLEXIGLAS BASE FLINTLASTIC PLY IV FLINTLASTIC FR-PFRP-N-B4 4 - FLEXIGLAS BASE FLINTLASTIC PLY IV (2 PLIES) FLINTLASTIC FR-PGTS-N-B2 2 GLASBASE - FLINTLASTIC GTS -GTS-N-B3 3 - FLEXIGLAS BASE FLINTGLAS PLY IV FLINTLASTIC GTSGTS-N-B4 4 - FLEXIGLAS BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC GTSFRBC-N-B3 3 GLASBASE - FLEXIGLAS FR BASE FLINTLASTIC FR CAPFRBC-N-B4 4 - FLEXIGLAS FR BASE FLINTGLAS PLY IV (2 PLIES) FLINTLASTIC FR CAPNEW / REPLACEMENT See description of the following specs under New / Replacement Nailable and Non-NailableINSULATEDSTA-N-B2/IN GMS-C-B2/ICSTA-N-B3/IN GMS-C-B3/ICSTA-N-B4/IN GMS-C-B4/ICSTA-C-B2/IC FRP-N-B2/INSTA-C-B3/IC FRP-N-B3/INSTA-C-B4/IC FRP-N-B4/INGTA-N-B2/IN FRP-C-B2/ICGTA-N-B3/IN FRP-C-B3/ICGTA-N-B4/IN FRP-C-B4/ICGTA-C-B2/IC GTS-N-B2/IN & (All New/Replacement Specs /IS)GTA-C-B3/IC GTS-N-B3/INGTA-C-B4/IC GTS-N-B4/INGTAFR-N-B2/IN GTS-C-B2/ICGTAFR-N-B3/IN GTS-C-B3/ICGTAFR-N-B4/IN GTS-C-B4/ICGTAFR-C-B2/IC FRBC-N-B3/INGTAFR-C-B3/IC FRBC-N-B4/INGTAFR-C-B4/IC FRBC-C-B2/INGMS-N-B2/IN FRBC-C-B3/INGMS-N-B3/IN FRBC-C-B4/INGMS-N-B4/INRECOVER See description of the following specs under New / Replacement Nailable and Non-NailableEXISTING ROOFSTA-N-B2/RN GMS-N-B2/RN FRBC-N-B3/RNSTA-N-B3/RN GMS-N-B3/RN FRBC-N-B4/RNSTA-N-B4/RN GMS-N-B4/RN FRBC-C-B2/RCSTA-C-B2/RC GMS-C-B2/RC FRBC-C-B3/RCSTA-C-B3/RC GMS-C-B3/RC FRBC-C-B4/RCSTA-C-B4/RC GMS-C-B4/RCGTA-N-B2/RN FRP-N-B2/RNGTA-N-B3/RN FRP-N-B3/RNGTA-N-B4/RN FRP-N-B4/RNGTA-C-B2/RC FRP-C-B2/RCGTA-C-B3/RC FRP-C-B3/RCGTA-C-B4/RC FRP-C-B4/RCGTAFR-N-B2/RN GTS-N-B2/RNGTAFR-N-B3/RN GTS-N-B3/RNGTAFR-N-B4/RN GTS-N-B4/RNGTAFR-C-B2/RC GTS-C-B2/RCGTAFR-C-B3/RC GTS-C-B3/RCGTAFR-C-B4/RC GTS-C-B4/RCRECOVEREXISTING ROOF(All New/Replacement Specs /R)INSULATION ADDED188

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!