12.07.2015 Views

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Roof Fasteners: Wood Decks1. COMPANY NAME CONSTRUCTION FASTENERS, INC. CONSTRUCTION FASTENERS, INC.2. PRODUCT NAME DEKFAST #15 HI-STRENGTH #14 DEKFAST STAINLESS STEEL3. COUNTRY OF MANUFACTURE U.S. U.S.4. USED WITH:Insulation Attachment X XBuilt-Up Membranes X XSingle-Ply Membranes X X5. MATERIAL TYPE HARDENED CARBON STEEL STAINLESS STEEL (TRIMRITE)6. COATING TYPE ORGANIC NONE7. SHANK TYPE SPIRAL THREAD SPIRAL THREAD8. POINT TYPE SELF-DRILLING SELF-DRILLING9. METHOD OF ATTACHMENT THREADED THREADED10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /FASTENING RANGE THICKNESS (inches) / PLYWOOD DECKPENETRATION (inches) / WOOD DECK PENETRATION(inches)0.264 1-1/4 1/4 3/4 1 0.235 1-1/4 1/2 3/4 10.264 2 1 3/4 1 0.235 2 1 3/4 10.264 3 2 3/4 1 0.235 3 2 3/4 10.264 4 3 3/4 1 0.235 4 3 3/4 10.264 5 4 3/4 1 0.235 5 4 3/4 10.264 6 5 3/4 1 0.235 6 5 3/4 10.264 7 6 3/4 1 0.235 7 6 3/4 10.264 8 7 3/4 1 0.235 8 7 3/4 10.264 10 9 3/4 1 0.235 10 9 3/4 10.264 12 11 3/4 1 0.235 12 11 3/4 10.264 14 13 3/4 10.264 16 15 3/4 10.264 18 17 3/4 10.264 20 19 3/4 10.264 22 21 3/4 10.264 24 23 3/4 10.264 26 25 3/4 111. HEAD SHAPE # 3 PHILLIPS TRUSS #3 PHILLIPS TRUSS12. HEAD DIMENSIONS (inches)Thickness 0.109 0.105Diameter 0.438 0.44013. PLATESRequired (yes/no) YES YESAvailable From Manufacturer (yes/no) YES YES14. PLATE SHAPE / DIMENSIONS (inches) / MATERIALHEXAGONAL 2-7/8 GALVALUME ROUND 2 GALVALUMEROUND 2 GALVALUME ROUND 3 GALVALUMEROUND 2-1/2 GALVALUME ROUND 3 PLASTIC15. INSTALLATION EQUIPMENTScrew Gun (optional/required) REQUIRED REQUIREDInstallation Tool With Screw Gun (optional/required) OPTIONAL OPTIONALSpecial Tool Needed (optional/required)Other16. AVERAGE PULLOUT RESISTANCE (lbs.)(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)3/4-inch plywood 703 5902-inch pine plank 2217 194317. MEETS THE FM APPROVAL REQUIREMENTS AS ACOMPONENT OF A CLASS I WOOD ROOF (yes/no) YES YES18. ACCEPTED BY THE FOLLOWING CODES FM, METRO-DADE COUNTY FM, METRO-DADE COUNTY19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES20. SEE APPENDIX IF CHECKED X XNA = not applicable406

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!