12.07.2015 Views

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Other Prefabricated Sheet-Applied Membranes Part 1: <strong>General</strong> Information1. COMPANY NAME BONDCOTE BONDCOTE BONDCOTE BONDCOTE CARLISLE CARLISLEROOFING ROOFING ROOFING ROOFING SYNTEC SYNTECSYSTEMS SYSTEMS SYSTEMS SYSTEMS INC. INC.2. PRODUCT NAME BONDCOTE BONDCOTE BONDCOTE BONDCOTE SURE-WELD SURE-SEAL350 SERIES 400 SERIES 500 SERIES FLEECEBOND & GSO POLYEPICHLO-1000 ROHYDRIN3. PRODUCT DESCRIPTIONReinforcement 18 X 12 18 X 12 18 X 12 18 X 12 POLYESTER NONEPOLYESTER POLYESTER POLYESTER POLYESTERColor WHITE WHITE WHITE WHITE WHITE, GRAY OR GRAY /TAN ON BLACKInstalled Weight (lbs./ft 2 w/o ballast)` 0.24 0.28 0.33 0.30 0.25 0.484. COATING REQUIRED: NONE NONE NONE NONE NONE NONE5. USE IN:New <strong>Roofing</strong> X X X X X XReroofing X X X X X X6. FIELD LAP JOINT METHOD HEAT WELD HEAT WELD HEAT WELD HEAT WELD HEAT WELD CONTACT7. TYPES OF ROOF SYSTEMSLoose Laid/Ballasted(ballast: lbs./ft 2 ) 10 10 10 10Partially Adhered (method) MECHANICALLY MECHANICALLY MECHANICALLY MECHANICALLY MECH. FAST.BLACKADHESIVEFully Adhered(method) CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES. CONT. ADHES.Protected Roof Membrane Assembly X X X X8. MINIMUM SLOPE REQUIRED (inches per foot) DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL 1/4"9. ACCEPTABLE SUBSTRATES(X=direct application permitted)(S=separator sheet required)(O=overlayment required in some or all circumstances)Glass Fiber X O X O X O XMineral Fiber X O X O X O X O OPolystyrene S O S O S O X O OCellular Glass X X X X X XPhenolicFiberboard X X X X X XPerlite X X X X O OPolyisocyanurate X X X X X XPolyurethane X X X X X XGypsum X X X X O X OConcrete O O O X O X OWood Plank O O O X O X OPlywood O O O X O X OExisting Built-up Membrane O O O X O X O10. RESTRICTED REGIONS (refer to manufacturer's literature) NONE NONE NONE NONE NONE NONE11. WORKABLE TEMPERATURE RANGE (degrees F) 0 – 180 0 – 180 0 – 180 0 – 180 –25 – 140 –20 – 18012. FLASHING MATERIAL ROOF MEMB ROOF MEMB ROOF MEMB ROOF MEMB REINFORCED & UNCUREDNBP-COATED NBP-COATED NBP-COATED NBP-COATED UNREINFORCED OR CUREDMETAL METAL METAL METAL MEMBRANE EPDM & ECO/CO13. FLASHING METHOD HEAT WELD & HEAT WELD & HEAT WELD & HEAT WELD & HEAT WELD & CONTACTCONTACT CONTACT CONTACT CONTACT CONTACT ADHESIVEADHESIVE ADHESIVE ADHESIVE ADHESIVE ADHESIVE14. PREFORMED ACCESSORIES AVAILABLE (yes/no) YES YES YES YES YES NO15. COUNTRY OF:Origin USA USA USA USA USA USAManufacture USA USA USA USA USA USA16. YEAR OF FIRST COMMERCIAL USEOutside USA 1987 1977Within USA 1977 1977 1995 1991 1991 197717. NUMBER OF SQUARES INSTALLED (100 ft 2 )Outside USAWithin USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS MILLIONS THOUSANDS18. METHODS OF DISTRIBUTION (distributors and/or direct) DIRECT DIRECT DIRECT DIRECT DISTRS, DIRECT DISTRS, DIRECT19. NUMBER OF REGIONAL LOCATIONS 4 4 4 4 70 7020. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES21. FOR SALES INFORMATION, CONTACT: SALES DEPT. SALES DEPT. SALES DEPT. SALES DEPT. C. KUHL C. KUHL800/368–2160 800/368–2160 800/368–2160 800/368–2160 717/245–7000 717/245–700022. FOR TECHNICAL INFORMATION, CONTACT: TECH. DEPT. TECH. DEPT. TECH. DEPT. TECH. DEPT. S. IBRAHIM S. IBRAHIM800/368–2160 800/368–2160 800/368–2160 800/368–2160 717/245–7000 717/245–700023. SEE APPENDIX IF CHECKED X X X244

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!