12.07.2015 Views

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Modified Bitumen Part 1 - <strong>General</strong> Information1. COMPANY NAME DANOSA DANOSA DANOSA DANOSA DANOSA DANOSACARIBBEAN CARIBBEAN CARIBBEAN CARIBBEAN CARIBBEAN CARIBBEANINC. INC. INC. INC. INC. INC.2. PRODUCT NAME GLASDAN GLASDAN GLASDAN GLASDAN ESTERDAN ESTERDANR-36 AL-80-3 RM RM-5 RM-5 RM-PLUS3. PRODUCT DESCRIPTIONType of Modifier SBS SBS SBS SBS SBS SBSThickness (mils) 140 120 140 173 177 197Top Surface BITUMEN ALUMINUM MINERAL MINERAL MINERAL MINERALGRANULES GRANULES GRANULES GRANULESReinforcing Material SMOOTH GLASS FIBER GLASS FIBER GLASS FIBER POLYESTER POLYESTERColors BLACK ALUMINUM WHITE / OTHER WHITE / OTHER WHITE / OTHER WHITE / OTHERInstalled Weight (lbs./ft 2 without ballast) 0.77 0.72 0.83 1.05 1.07 1.194. KINDS OF FIELD SURFACING REQUIRED COATING NONE NONE NONE NONE NONEBALALST5. USE INNew <strong>Roofing</strong> X X X X X XReroofing X X X X X X6. FIELD LAP JOINT METHOD HOT MOP OR TORCH HOT MOP OR HOT MOP OR HOT MOP OR HOT MOP ORTORCH TORCH TORCH TORCH TORCH7. TYPES OF ROOF SYSTEMS:Loose Laid/Ballasted (ballast: lbs./ft 2 )Partially Adhered (method)Fully Adhered (method) MOP OR TORCH MOP OR TORCH MOP OR TORCH MOP OR TORCH MOP OR TORCH MOP OR TORCHProtected Roof Membrane Assembly8. MINIMUM SLOPE REQUIRED DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL DEAD LEVEL9. ACCEPTABLE SUBSTRATES(X=direct application permitted)(O=overlayment required in some/all circumstances)Glass Fiber X X X X X XMineral Fiber X X X X X XPolystyrene O O O O O OCellular Glass X O X O X O X X O X OPhenolic X O X O X O O X O X OFiberboard O O O O O OPerlite O O O X O X OPolyisocyanurate O O O O O OPolythane O O O O O OGypsum O O O O O OConcrete X X X X X XWood Plank X O X O X O X O X OPlywood X O X O X O X O X OExisting Built-up Membrane O O O O O O10. RESTRICTED REGIONS (refer to manufacturer's literature) NONE NONE NONE NONE NONE NONE11. WORKABLE TEMPERATURE RANGE (degrees F) 14 – 120 14 – 120 14 – 120 14 – 120 14 – 120 14 – 12012. FLASHING MATERIAL GLASD AL-80 SAME SAME SAME SAME SAMEOR MATERIAL OR MATERIAL OR MATERIAL OR MATERIAL OR MATERIAL ORESTERDAN RM ESTERDAN RM GLASDANAL-80 ESTERDAN RM GLASDANAL-80 GLASDANAL-8013. FLASHING METHOD HOT MOP HOT MOP HOT MOP HOT MOP HOT MOP HOT MOPOR TORCH OR TORCH OR TORCH OR TORCH OR TORCH OR TORCH14. PREFORMED ACCESSORIES AVAILABLE (yes/no) NO NO NO NO NO NO15. COUNTRY OF:Origin PUERTO RICO PUERTO RICO PUERTO RICO PUERTO RICO PUERTO RICO PUERTO RICOManufacture PUERTO RICO PUERTO RICO PUERTO RICO PUERTO RICO PUERTO RICO PUERTO RICO16, YEAR OF FIRST COMMERCIAL USEOutside USAWithin USA 1979 1988 1988 1988 1985 199517. NUMBER OF SQUARES INSTALLED (100 ft 2 )Outside USA MILLIONS MILLIONS MILLIONS MILLIONS MILLIONSWithin USA THOUSANDS THOUSANDS THOUSANDS THOUSANDS THOUSANDS18. METHODS OF DISTRIBUTION (distributors and/or direct) DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT DISTRS,DIRECT19. NUMBER OF REGIONAL LOCATIONS 2 2 2 2 2 220. LICENSED APPLICATOR AGREEMENT (yes/no) YES YES YES YES YES YES21. FOR SALES INFORMATION, CONTACT: W. RIVERA W. RIVERA W. RIVERA W. RIVERA W. RIVERA W. RIVERA22. FOR TECHNICAL INFORMATION, CONTACT: F. ROMERO F. ROMERO F. ROMERO F. ROMERO F. ROMERO F. ROMERO23. SEE APPENDIX IF CHECKED90

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!