12.07.2015 Views

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Roof Fasteners: Concrete DecksCOMPANY NAME CARLISLE SYNTEC CARLISLE SYNTEC INCORPORATED2. PRODUCT NAME HP FASTENER HP CONCRETE SPIKE3. COUNTRY OF MANUFACTURE U.S. U.S.4. USED WITH:Insulation Attachment X XBuilt-Up MembranesXSingle-Ply Membranes X X5. MATERIAL TYPE CARBON STEEL CARBON STEEL6. COATING TYPE EPOXY ELECTRODEPOSITION EPOXY ELECTRODEPOSITION7. SHANK TYPE SINGLE LEAD, BUTTRESS THREAD --8. POINT TYPE NA NA9. METHOD OF ATTACHMENT THREADED SHANK COMPRESSION10. SHANK DIAMETER (inches) / SHANK LENGTH (inches) /FASTENING RANGE THICKNESS (inches) / DECKPENETRATION (inches)0.240 1-1/2 1/4 1-1/40.180 1-3/4 1/2 1-1/4 0.240 2 3/4 1-1/40.180 2-1/4 1 1-1/4 0.240 2-1/2 1-1/4 1-1/40.180 2-3/4 1-1/2 1-1/4 0.240 3 1-3/4 1-1/40.180 3-1/4 2 1-1/4 0.240 3-1/2 2-1/4 1-1/40.180 4-1/4 3 1-1/4 0.240 4 2-3/4 1-1/40.180 5 3-3/4 1-1/4 0.240 4-1/2 3-1/4 1-1/40.180 6 4-3/4 1-1/4 0.240 5 3-3/4 1-1/40.240 5-1/2 4-1/4 1-1/40.240 6 4-3/4 1-1/40.240 6-1/2 5-1/4 1-1/40.240 7 5-3/4 1-1/40.240 7-1/2 6-1/4 1-1/40.240 8 6-3/4 1-1/40.240 8-1/2 7-1/4 1-1/40.240 9 7-3/4 1-1/40.240 9-1/2 8-1/4 1-1/40.240 10 8-3/4 1-1/40.240 10-1/2 9-1/4 1-1/40.240 11 9-3/4 1-1/40.240 12 10-3/4 1-1/40.240 13 11-3/4 1-1/40.240 12 10-3/4 1-1/40.240 12 10-3/4 1-1/40.240 12 10-3/4 1-1/411. HEAD SHAPE WAFER TRUSS12. HEAD DIMENSIONS (inches)Thickness 0.150 0.110Diameter 0.430 0.44013. PLATESRequired (yes/no) YES YESAvailable From Manufacturer (yes/no) YES YES14. PLATE SHAPE / DIMENSIONS (inches) / MATERIALSQUARE W/ROUNDEDSQUARE W/ROUNDEDCORNERS 2-7/8 GALVALUME CORNERS 2-7/8 GALVALUMEROUND 2 PLASTIC ROUND 2 GALVALUMEROUND 2 GALVALUME ROUND 2-3/8 GALVALUMEROUND 3 PLASTIC15. INSTALLATION EQUIPMENTScrew Gun (optional/required)REQUIREDInstallation Tool With Screw Gun (optional/required)Special Tool Needed (optional/required)SDS SPIKE HAMMER (OPTIONAL)OtherHAMMER (REQURIED)16. AVERAGE PULLOUT RESISTANCE (lbs.)(FM TINIUS OLSEN PULLOUT RESISTANCE TESTS)3,000 PSI AGED 28 DAYS) -- --17. MEETS THE FM APPROVAL REQUIREMENTS AS ACOMPONENT OF A CLASS I CONCRETE ROOFCONSTRUCTION (yes/no) YES YES18. ACCEPTED BY THE FOLLOWING CODES FM FM19. MANUFACTURER WARRANTY AVAILABLE (yes/no) YES YES20. SEE APPENDIX IF CHECKEDNA = not applicable434

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!