12.07.2015 Views

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Metal Roof Panels1. COMPANY NAME MBCI MBCI2. PRODUCT NAME CRAFTSMAN SERIES HIGH BATTEN CRAFTSMAN SERIES LARGE BATTEN3. ARCHITECTURAL APPLICATIONS (yes/no) YES YESSTRUCTURAL APPLICATIONS (yes/no) NO NOPANEL CONFIGURATION4A. Panel Description LOCK FORM SEPARATE BATTEN LOCK FORM SEPARATE BATTEN4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHESGalvanized Steel (ga.)Stainless Steel (ga.)Galvalume (ga.)Aluminized Steel (ga.)22, 24, 26 / BARE, COLOR BOND, SIGNATURE 22, 24, 26 / BARE, COLOR BOND, SIGNATURE200, 300 (PVDF), OR 300 METALLIC 200, 300 (PVDF), OR 300 METALLICAluminum (ga.)Copper (ga.)Terne Metal (ga.)Zinc (ga.)4C. MAXIMUM LENGTH (lf.) 50 (STANDARD) 50 (STANDRAD)4D. PANEL WIDTHS (in.) 12, 16-1/2 12, 16-1/25. SYSTEMS REQUIREMENTSMinimum Slope (in. per ft.) 3:12 3:12Solid Decking (required, optional, or not used) REQUIRED REQUIREDUnderlayment (type or NA) 30-LB. FELT OR EQUIVALENT 30-LB. FELT OR EQUIVALENT6. PANEL PROFILEVertical LegTrapezoidalBatten X XOther (specify)7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;E = FIELD APPLIED; N = NONEE = FIELD APPLIED; N = NONEOverlappedCrimped (45 degrees)Roll Formed (180 degrees)Double Roll Formed (two 180 degrees)Roll and LockSnap-on Cap 2 / F 2 / FSnap Together8. FASTENING METHODThrough-Fastened, ExposedThrough-Fastened, ConcealedCLIP, CONCEALEDFixed ClipSlip Clip X XMoveable Clip (designed allowable movement, inches)9. SPECIALTY APPLICATIONSCurvedTaperedOther TRANSITION, ROOF TO FASCIA, MANSARD TO SOFFIT TRANSITION, ROOF TO FASCIA, MANSARD TO SOFFIT10. MANUFACTURER/PRODUCT DATAYear of First Commercial Use 1983 1983Number of Squares InstalledLicensed Applicator Agreement (yes/no) NO NOMethod of Distribution (distributors, direct) DIRECT DIRECTNumber of Regional Service Locations 21 21For Sales Information, Contact: W. DICKINSON W. DICKINSONFor Technical Information, Contact: T. WOLFE T. WOLFE11. ASTM E331 WATER PENETRATION TEST RESULTS NO LEAKAGE @ 4 PSF NONE(results or none)12, ASTM E 1646 WATER PENETRATION TEST RESULTS(results or none)13. ASTM E283 AIR INFILTRATION TEST RESULTS 0.048 CFM/SQ FT @ 4 PSF; NONE(results or none)0.045 CFM/SQ FT14. ASTM E 1680 (AIR INFILTRATION TEST RESULTS(results or none)15. FM/UL WIND UPLIFT RATINGS FOR ANY SPECIMEN UL-90 UL-9016. SEE APPENDIX IF CHECKEDNA=not applicable302

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!