12.07.2015 Views

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Metal Roof Panels1. COMPANY NAME FOLLANSBEE STEEL GALVAMET, INC.2. PRODUCT NAME TERNE II GALVALOK I3. ARCHITECTURAL APPLICATIONS (yes/no) YES YESSTRUCTURAL APPLICATIONS (yes/no) NO YESPANEL CONFIGURATION4A. Panel Description DOUBLE LOCK STANDING SEAM STANDING SEAM4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHESGalvanized Steel (ga.)Stainless Steel (ga.)22, 24, 26 / BARE, MODIFIEDPOLYESTER, KYNAR 500Galvalume (ga.)Aluminized Steel (ga.)Aluminum (ga.)Copper (ga.)Terne Metal (ga.)28, 30 / ACRYLIC SHOP COATZinc (ga.)4C. MAXIMUM LENGTH (lf.) 35 454D. PANEL WIDTHS (in.) 17, 21 12, 18, 245. SYSTEMS REQUIREMENTSMinimum Slope (in. per ft.) 3:12 1/4:12Solid Decking (required, optional, or not used) REQUIRED OPTIONALUnderlayment (type or NA) ROSIN SIZED PAPER RIGID BOARD, ISO, FLEXIBLE FIBERGLASS6. PANEL PROFILEVertical LegXTrapezoidalBattenOther (specify)7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;E = FIELD APPLIED; N = NONEE = FIELD APPLIED; N = NONEOverlappedCrimped (45 degrees)Roll Formed (180 degrees)Double Roll Formed (two 180 degrees) 1 / NRoll and LockSnap-on CapSnap Together 3 / F8. FASTENING METHODThrough-Fastened, ExposedThrough-Fastened, ConcealedCLIP, CONCEALEDFixed Clip X XSlip ClipXMoveable Clip (designed allowable movement, inches) X 2-1/29. SPECIALTY APPLICATIONSCurvedXTaperedOther10. MANUFACTURER/PRODUCT DATAYear of First Commercial Use 1998 1995Number of Squares InstalledLicensed Applicator Agreement (yes/no)NOMethod of Distribution (distributors, direct) DISTRIBUTORS DIRECTNumber of Regional Service Locations 22For Sales Information, Contact: J. BONAR J. GEORTNERFor Technical Information, Contact: E. THOMAS J. GEORTNER11. ASTM E331 WATER PENETRATION TEST RESULTS NONE NO LEAKAGE @ 4 PSF(results or none)X12, ASTM E 1646 WATER PENETRATION TEST RESULTS(results or none)13. ASTM E283 AIR INFILTRATION TEST RESULTS NONE 0.043 CFM; 0.029 CFM;(results or none)0.022 CFM @ 4 PSF14. ASTM E 1680 (AIR INFILTRATION TEST RESULTS(results or none)15. FM/UL WIND UPLIFT RATINGS FOR ANY SPECIMEN NONE UL-9016. SEE APPENDIX IF CHECKEDNA=not applicable298

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!