12.07.2015 Views

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

General Index - National Roofing Contractors Association

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Metal Roof Panels1. COMPANY NAME ENGLERT, INC. ENGLERT, INC.2. PRODUCT NAME SERIES 2500 SERIES 10003. ARCHITECTURAL APPLICATIONS (yes/no) YES YESSTRUCTURAL APPLICATIONS (yes/no) YES NOPANEL CONFIGURATION4A. Panel Description MECHANICAL SEAM SNAP-LOCK4B. PANEL MATERIALS, THICKNESSES, AND FINISHES THICKNESSES / FINISHES THICKNESSES / FINISHESGalvanized Steel (ga.) 22, 24 / KYNAR 550, 22, 24 / KYNAR 550,Stainless Steel (ga.)HYLAR 5000, MILLHYLAR 5000, MILLGalvalume (ga.) 22, 24 / KYNAR 500, 22, 24 / KYNAR 500,HYLAR 5000, MILLHYLAR 5000, MILLAluminized Steel (ga.)Aluminum (ga.) 0.032, 0.040 / KYNAR 500, 0.032 / KYNAR 500,HYLAR 5000 HYLAR 5000Copper (ga.) 16, 20 16Terne Metal (ga.) 26Zinc (ga.)4C. MAXIMUM LENGTH (lf.) 200 2004D. PANEL WIDTHS (in.) 12, 16, 18 12, 16, 205. SYSTEMS REQUIREMENTSMinimum Slope (in. per ft.) 1/4:12 3:12Solid Decking (required, optional, or not used) OPTIONAL REQUIREDUnderlayment (type or NA) 30-LB. FELT 30-LB. FELT6. PANEL PROFILEVertical Leg X XTrapezoidalBattenOther (specify)7. SEAM PROCESSING: HEIGHT (inches) & SEALANT HEIGHT(S) (inches) / HEIGHT(S) (inches) /SEAM SEALANT: F= FACTORY APPLIED; SEAM SEALANT: F= FACTORY APPLIED;E = FIELD APPLIED; N = NONEE = FIELD APPLIED; N = NONEOverlappedCrimped (45 degrees) 2 / FRoll Formed (180 degrees)Double Roll Formed (two 180 degrees)Roll and LockSnap-on CapSnap Together 1-1/2 / N8. FASTENING METHODThrough-Fastened, ExposedThrough-Fastened, ConcealedCLIP, CONCEALEDFixed Clip X XSlip ClipMoveable Clip (designed allowable movement, inches)X9. SPECIALTY APPLICATIONSCurvedTaperedOther10. MANUFACTURER/PRODUCT DATAYear of First Commercial Use 1993 1993Number of Squares InstalledLicensed Applicator Agreement (yes/no) YES NOMethod of Distribution (distributors, direct) DIRECT DIRECTNumber of Regional Service Locations 10 10For Sales Information, Contact: K. CORCORAN K. CORCORANFor Technical Information, Contact: J. TRIPOD J. TRIPOD11. ASTM E331 WATER PENETRATION TEST RESULTS 15.1 PSF/15 MIN = 0 NONE(results or none)12, ASTM E 1646 WATER PENETRATION TEST RESULTS(results or none)13. ASTM E283 AIR INFILTRATION TEST RESULTS 6.24 PSF/MAX .013 CFM/FT SQ NONE(results or none)14. ASTM E 1680 (AIR INFILTRATION TEST RESULTS(results or none)15. FM/UL WIND UPLIFT RATINGS FOR ANY SPECIMEN FM I-90, UL-9016. SEE APPENDIX IF CHECKEDNA=not applicableUL 90294

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!