Electrical DataSmall Pump AccessoriesElectrical dataThe table shows current data and suggests a suitable fuse rating.Starting current is drawn for less than one second and slow blowfuses should be used to prevent unnecessary rupture during starting.Pump outfits are rated for operation above 12°C. Pump starting attemperatures lower than 12°C will increase the current drawn due tothe higher start torque required. This may cause the motor thermaloverload to trip.Three-phase motors should be protected by a starter consisting of asuitably rated contactor and thermal overload. The trip currentregulator on the thermal overload should be set according to thestarter manufacturer's instructions.Full loadcurrent(A)Start current(A)Suggestedfuse rating(A)Electrical Supply 50 Hz 60 Hz 50 Hz 60 HzE2M0.7200-240 V 1-ph 50/60 Hz 1.0 1.0 2.8 2.3 6100-120 V 1-ph 50/60 Hz 1.8 1.9 5.7 5.3 10E2M1.5200-240 V 1-ph 50/60 Hz 1.4 1.3 5.5 5.2 6100-120 V 1-ph 50/60 Hz 3.1 2.6 12.0 11.2 10RV3 and RV5220-240 V 1-ph 50/60 Hz 2.7 2.1 17.0 17.0 5110-120 V 1-ph 50/60 Hz 4.4 4.4 30.8 30.8 10200 V 1-ph 50/60 Hz 2.9 2.4 17.6 17.2 5200-220 V 3-ph 50/60 Hz 1.7 1.7 10.2 10.2 2.5380-415/460 V 3-ph 50/60 Hz 1.0 1.0 5.7 7.0 2.5RV8 and RV12220-240 V 1-ph 50/60 Hz 3.4 3.4 17.0 18.0 5110-120 V 1-ph 50/60 Hz 7.8 6.9 34.0 30.8 13200 V 1-ph 50/60 Hz 4.0 4.0 17.6 17.2 5200-220 V 3-ph 50/60 Hz 2.5 2.9 14.0 12.0 4.0380-415/460 V 3-ph 50/60 Hz 1.5 1.5 9.0 8.7 2.5E1M18 and E2M18220-240 V 1-ph 50/60 Hz 4.6 5.0 33.0 33.0 15110-120 V 1-ph 50/60 Hz 11.0 10.0 42.0 32.0 30200 V 1-ph 50/60 Hz 6.0 5.5 44.0 44.0 15100 V 1-ph 50/60 Hz 12.0 11.0 88.0 88.0 30200-230 V 3-ph 50/60 Hz 3.3 2.3 16.1 15.9 10380-415/460 V 3-ph 50/60 Hz 1.9 1.6 10.2 10.6 6E2M28220-240 V 1-ph 50/60 Hz 6.0 6.5 27.0 32.0 15110-120 V 1-ph 50/60 Hz 12.0 12.0 36.0 50.0 30200 V 1-ph 50/60 Hz 6.5 5.5 40.0 40.0 20100 V 1-ph 50/60 Hz 12.0 12.0 80.0 80.0 30200-230 V 3-ph 50/60 Hz 3.8 3.9 22.8 22.0 16380-415/460 V 3-ph 50/60 Hz 2.3 2.3 14.3 14.6 10XDS35i200-230 V 1-ph 50/60 Hz 6.6 6.6 - - 16 (13 UK)100-120 V 1-ph 50/60 Hz 10.6 10.6 - - 20XDS46i and XDS100B200-230 V 1-ph 50/60 Hz 6.6 6.6 - - 16 (13 UK)100-120 V 1-ph 50/60 Hz 10.6 10.6 - - 20nXDS100-127 V 1-ph 50/60 Hz 10.0 10.0 - - 13200-240 V 1-ph 50/60 Hz 6.0 6.0 - - 10This diagram shows the accessories available for oil-sealed pumps.Refer to the following pages for details of each accessory. Note thatthe E-LAB2 pump is supplied with all required accessories.4 53131 Outlet mist filter12 Oil return kit23 Small volume inlet liquid catchpot4 ITO20K inlet liquid catchpot5 ITC20K inlet chemical trap6 ITF20K inlet dust filter7 FL20K foreline trap8121 EMF filter shown2 RV adjustable gas ballast oil return kit shown3 RV pump extension kit shown4?Not required for EM pumps276OIL11108 Vibration isolators9 Oil drain kit310 OB20 oil box purge adaptor11 Oil change reminder card12 RV gas ballast adaptor413 EBV20 solenoid operated gas ballastvalve191Page41Shop online at www.edwardsvacuum.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!