Technical Overview of the Cryotherapy SystemFigure D-8. Removing CryotipFigure D-9. Placing Protector Tube on ProbeFigure D-10. Removing Plastic Sleeve and Inserting Rubber Stopper• Wash the cryotip and plastic sleeve with soapy water until visiblyclean. Ensure that the rubber stopper does not fall out duringwashing.• Rinse the cryotip and plastic sleeve thoroughly with water. Allowthem to air-dry.• After cleaning and drying the cryotip and plastic sleeve, they shouldbe:• high-level disinfected by boiling or steaming, or by soaking inhigh-level disinfectant chemicals (e.g., 1% chlorine [made withboiled water] or 2–4% glutaraldehyde); or• sterilized with steam (autoclave), dry heat (dry heat oven), or gas(gas sterilizer).Cervical Cancer Prevention Guidelines for Low-Resource Settings D-7