CADS MessagesCADS340W — CATRACE FAILED-RC=xx, COMPID=yyy, FN=zzzzzzzzReason:The AR command CATRACE was issued at the VSE operator console, but themodule responsible for enabling/disabling the trace could not be successfullyexecuted. RC is the return code of the trace module. COMPID is the componentdesignator of the trace program, and FN is the function associated with the trace.Action:When the return code is 4 or 8, it usually means that the library containing thetrace program was not available during CASAUTIL initialization. No action canbe taken in this case. Other return codes are explained by the particular tracecommand description.CADS350E — STORAGE ERROR FOR SVC 4 INTERCEPT OF xxxxxxxxReason:This message is issued by CASALODA when attempting to build an SVC 4reentry routine via the SAVER function, where insufficient system GETVISstorage is available. The SVC 4 intercept of the phase (xxxxxxxx) is bypassed.Action:Increase the amount of system GETVIS available.CADS351E — SAVER ERROR FOR SVC 4 INTERCEPT OF xxxxxxxxReason:This message is issued by CASALODA when attempting to build an SVC 4reentry routine via the SAVER function, and an unexpected return code wasreceived. The SVC 4 intercept of the phase (xxxxxxxx) is bypassed.Action:<strong>Contact</strong> CA <strong>Technical</strong> <strong>Support</strong>.3–156 Message Guide