VSAMVSAMError CodesThe following return codes are issued by CAICUI in response to VSAMprocessing errors. The return codes issued by CAICUI also contain return codesissued by IBM components. Refer to the appropriate IBM publication for adescription of those return codes.000404zz — NO STORAGE FOR VSAM CONTROL BLOCKSReason:There is insufficient partition GETVIS to allocate the VSAM control blocksnecessary to access the data set. The GETVIS return code is displayed in the 'zz'position of the return code.Action:Determine the cause of the error and allocate additional partition GETVIS.000408zz — GENCB/ACB ERRORReason:An error occurred while attempting to generate the VSAM ACB. The VSAMGENCB return code is displayed in the 'zz' position of the return code.Action:Determine the cause of the error and perform the steps necessary to correct thecondition.00040Czz — GENCB/RPL ERRORReason:An error occurred while attempting to generate the VSAM RPL. The VSAMGENCB return code is displayed in the 'zz' position of the return code.Action:Determine the cause of the error and perform the steps necessary to correct thecondition.9–10 Message Guide