LED ON FaultElectrovalveGlowing indicates “Extinguishment” in course Fast blinking indicates power supply failure tothe electrovalve connected to output EV, or thatthe latter is either open or shortedPreExt.Glowing indicates “Pre-Extinguishment” in courseFast blinking indicates that terminals [+] and [–]of output PR are either disconnected or shortedManualExt.Glowing indicates that input EM has been activatedFast blinking indicates that terminals [+] and [–]of input EM are either disconnected or shortedDisab.Ext.Glowing indicates that input IE has been activatedFast blinking indicates that terminals [+] and [–]of input IE are either disconnected or shortedPres.SwitchGlowing indicates that the input PS has been activated,due to low extinguishant gas pressureFast blinking indicates that terminals [+] and [–]of input PS are either disconnected or shortedLogic — Fast blinking indicates “blocked” ExtinguishmentUnitBoardDisable Glowing indicates “Extinguishment” is inhibitedExtinguish.DisableManualExtinguish.DisableAutomaticExtinguish.Glowing indicates “Manual Extinguishment” isinhibitedGlowing indicates that “Automatic Extinguishment”is inhibitedTable 1 (continued from page 9) … Description of the LEDsDescription of the Control keysThe Control panel keys can be activated by Keyswitchand PIN Code Users ONLY (Access level 2 — Key turnedin keyswitch or PIN Code entered — refer to“Access to Signalling and Commands”), unless otherwisestated.KeyDESCRIPTIONSilence This key can be used to restore the Silenceable outputs to standby status (terminals [NAC1], [NAC2],[DL], [TROUBLE], [ALARM — if duly programmed] and [Rn — if duly programmed]. Silence statuswill be held until the Silence key is pressed again or, if the Control panel is operating in Night Mode,until the Night mode Silence time expires or until a new Alarm/Trouble condition is detected.Ack./ Evac. This key can be used to refresh the “Pre-Alarm Time” or trigger an Alarm:For all persons on the premises: If this key is pressed for over 5 seconds during “Pre-Alarm Time”,the system will generate an alarm.For Key and PIN Code Users ONLY (Access level 2): If this key is pressed during “Pre-AlarmTime”, the remaining Pre-Alarm Time will be refresh with the programmed Investigation Time.Ifitispressed for over 5 seconds during “Pre-Alarm Time”, the system will generate an alarm.Reset This key can be used to reset the Fire detectors and restore all outputs to standby status (Supervised/Silenceableoutputs, NON-Supervised/Non-Silenceable outputs and Alarm zone outputs).Disab. Buzzer This key can be used to disable the buzzer. The buzzer will be re-enable if any kind of event occurs.Night Mode This key can be used to switch from Day to Night Mode.Disab./Fault This key can be used to disable the Bypassable Fire alarm outputs (terminals [NAC1] and [NAC2]).NACDisab./Fault This key can be used to disable the Telephone device output (terminal [DL])TelecomTest This key can be used to test the zones, buzzer and LEDs . If this key is pressed (when the Control panelis functioning as intended), all the LEDs will Glow and the buzzer will emit a continuous beep.For Access level 2 Users ONLY: If this key is pressed with the Disable key of a zone (z1, z2, .., z24)it will activate the respective zone test phase.z1 … z24 These keys can be used to disable their respective zones. Disabled zones will provide visual signallingof fire and fault conditions but will not activate any outputs or store events in Memory.Disable This key can be used to disable the “Extinguishment” function.Extinguish.Disable This key can be used to disable the “Manual Extinguishment” function. If this function is disabled, itManual will not be possible to activate Extinguishment function via the EM input.Extinguish.DisableAutomaticExtinguish.Table 2 Description of keysThis button can be used to disable the “Automatic Extinguishment” function. If this function is disabled,the zones will not be unable to activate Extinguishment”.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!