Access Level 2Most of the functions provided by this Control panel areavailable at Access Level 2. Therefore, only Key andPIN Code Users can operate the system (PIN Code enteredor Key turned in the Keyswitch).Using a Key To activate Access Level 2: insert the keyinto the Keyswitch and turn it horizontally — access willbe indicated by a beep.To exit Access Level 2: turn the key back and remove itfrom the Keyswitch — the Control panel will holdAccess Level 2 for a further 20 seconds then will emittwo beeps to indicate the end of Access Level 2 status.Using a PIN Type in the PIN Code for Access Level 2(1234 at Default): — access will be indicated by a fivebeeps in rapid succession.To exit Access Level 2: DO NOT press any buttons for20 seconds: the end of Access Level 2 status will be indicatedby two beeps in rapid succession.Investigation Time (Ack./Evac. button)The Ack./Evac. button will allow you to extendPre-alarm Time (in order to verify an Alarm).If you press Ack./Evac. button, the Pre-alarm Time willbe refreshed with the pre-set Investigation Time.The Ack./Evac. button functions only during thePre-alarm phase (Pre-al. LED ON).To activate the Investigation Time:1. Enter the PIN Code or turn the key in the Keyswitch(Access Level 2).2. Press and hold the Ack./Evac. button for at least 5seconds: theAck./Evac. LED will go On to indicatethat the Investigation Time is running.Investigation Time can be requested once only.Evacuation (Ack./Evac. button)You can also use the Ack./Evac. button to activate anEvacuation Alarm.To activate an Alarm when the Control panel is inPre-alarm status (Pre-al. LED ON), press and hold theAck./Evac. button AT LEAST 5 seconds.To activate an Alarm when the Control panel is inStandby status:1. Enter the PIN Code or turn the key in the Keyswitch(Access Level 2).2. Press the Ack./Evac. button for at least 5 seconds.SilenceThe Silence button will allow you to stop the signallingdevices. To Silence the signalling devices:1. Enter the PIN Code or turn the key in the Keyswitch(Access Level 2).2. Press Silence.DisableIf an Alarm detector is not working properly or is causingfalse Alarms (signalled by fast blinking on the Disabled/Fault/TestLED), you can exclude it from the system(turn it Off) by pressing the respective zone button.It is also possible to Disable Alarm signalling devices(Bells, Sirens, Fire signs, etc.)by pressing the Disab./FaultNAC button, and the Dialler by pressing theDisab./Fault Telecom Button.ResetDisabled devices will not activate in the event of anAlarm.The Reset button will allow you to Reset the Control panel(stop the Signalling devices, reset detectors andclear the memory). To Reset te Control panel:1. Enter the PIN Code or turn the key in the Keyswitch(Access Level 2).2. Press Reset.TestIf you want to Reset the Control panel after anAlarm (also triggered by just one zone), you mustfirst press the Silence button.The Test button will allow you to check the working orderof the Control panel LEDs and Buzzer.Extinguishment ModuleThis Control panel is equipped with an ExtinguishmentModule for fire extinguishment purposes (up to 2 ExtinguishmentModules can be connected to J424 Controlpanels). These devices have been specially designedto reduce unnecessary activation of fire fighting devices.In the event of a Fire, the Fire Extinguishment deviceswill be activated when the pre-set Pre-ExtinguishmentTime expires.These devices can also be activated from manualcall-points (ask your Installer for details).4 Conventional Fire Panels J424/J408

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!