CONVENTIONAL FIRE PANELS - Kotesa

CONVENTIONAL FIRE PANELS - Kotesa

CONVENTIONAL FIRE PANELS - Kotesa

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Activation ModeThis section will allow you to select the logic that will activatethe Extinguishment phase, as follows.OR If you ENABLE this option, at least ONE of the Zones— selected in the Zones chart — must detect alarmconditions.At least TWO If you ENABLE this option, at least TWOof the Zones — selected in the Zones chart — must detectalarm conditions.All If you ENABLE this option, ALL the Zones — selectedin the Zones chart — must detect alarm conditions. TimesThis section will allow you to set the Extinguishment Times.Pre-Extinguishment Time This field will allow you toprogram a delay between verification of the ActivationMode conditions and activation of the Electrovalve output([EV] terminals). The Pre-Extinguishment output([PR] terminals) will be active during the Pre-ExtinguishmentTime.Accepted values: 0 to 1275 seconds (21 minutes 15 seconds)in steps of 5 secondsDefault value: 20 secondsExtinguishment Time This field will allow you to setthe Extinguishment Time. If you DISABLE the Bistableoption, the EV output will restore to standby when theprogrammed Extinguishment Time expires.Accepted values: 0 to 250 seconds (4 minutes 10 seconds)in steps of 1 secondBistable If you ENABLE the Bistable option, the EVoutput will restore to standby when the Control panelResets. ZonesThis section will allow you to select the Zones which willactivate the Extinguishment phase. Manual Extinguishment InputThis field will allow you to set up the Standby status ofthe Manual Extinguishment Input ([EM] terminals).Normally Closed If this option is DISABLED (at Default),there must be a 3900 ohm resistance across the [+]and [–] terminals of the EM Input during Standby status. Pressure Switch InputThis field will allow you to set up the Standby status ofthe Pressure Switch Input ([PS] terminals).Normally Closed If this option is DISABLED (at Default,there must be a 3900 ohm resistance across the [+]and [–] terminals of the PS input during Standby status.Extinguishment Confirmation If you ENABLE thisoption, the Activated Extinguishment output ([AE] terminals)will activate if the Pressure Switch Input ([PS]terminals) activates during the Extinguishment Time.If you DISABLE this option (DISABLED at Default), theActivated Extinguishment output ([AE] terminals) willactivate when the Extinguishment Time starts.Enrolling: Power Supply StationsThe Power Supply Stations page will allow you to enroland set up Power Supply Stations, as follows. Enrol the Power Supply Stations (if installed).A tick () indicates that the respective Power SupplyStation is part of the system.Description This 16 character field will allow you to assigna label to the respective Power Supply Station. Forexample, it may be useful to assign the name of thearea where the device is located. The assigned labelwill identify the Power Supply Station in all the operationsit is involved in.Enrolling: Repeaters and LCD ModulesThe Repeaters and LCD Modules page will allow youto enrol Repeater panels and LCD Modules, as follows. Enrol the Repeater panels and Display Modules (ifinstalled).A tick () indicates that the respective device is part ofthe system.Description This 16 character field will allow you to assigna label to the respective device. For example, itmay be useful to assign the name of the area where thedevice is located. The assigned label will identify the devicein all the operations it is involved in. Disable Extinguishment InputThis field will allow you to set up the Standby status ofthe Disable Extinguishment Input ([IE] terminals).Normally Closed If this option is DISABLED (at Default),there must be a 3900 ohm resistance across the [+]and [–] terminals of the IE input during Standby status.38 Conventional Fire Panels J424/J408

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!