Day to Night Mode This field will allow you to programwhen the Control panel must change from Day to NightMode.This setting requires two digits for the Hour value andtwo for the Minutes value.Use 00 to 23 (00 = Midnight) to set the Hour value.Use 00 to 59 to set the Minutes value. ResetThe Control panel Reset operation is divided into twophases: Reset and Stabilization.During the Reset phase, the Control panel will interruptthe power supply to the devices connected to the Zonesand the [24R] terminal.During the Stabilization phase, the Control panel willignore the status of the Zones.This process is necessary, as some devices signal troubleconditions for several seconds after power-up.The Reset section will allow you to program the DetectorReset and Stabilization Times.Detector Reset Time This field will allow you to programthe length of the power interruption that will resetthe Detectors.Accepted values: 0 through 15 seconds, in steps of 1second.Default setting: 8 seconds. Alarm Verification TimeThis field will allow you to program the Alarm verificationwindow, that is, the time within which a Zone (with theAlarm Verification option ENABLED) must trigger twoAlarm events in order for the system generate a Controlpanel Alarm.Accepted values: 0 through 600 seconds (10 minutes),in steps of 5 secondsDefault setting: 30 seconds Night Mode Silence TimeThis parameter determines how long the Control panelwill hold “Silence” status during Night Mode.Accepted values: 0 through 600 seconds (10 minutes),in steps of 5 secondsDefault setting: 60 seconds Mains Failure Signalling DelayThis parameter determines how long the Control panelwill wait before signalling a Mains Failure event.Accepted Values: 0 through 9999 minutes (6 days, 22hours, 39 minutes), in steps of 1 minute.Default Setting: 0 minutes.A The IMQ SECURITY SYSTEMS approval appliesONLY when the Mains Failure delay is set at 30minutes or less. Date/TimeThis field is for the current date and time.Detector Stabilization Time This field will allow youto program the length of time (necessary after Reset)that the system will ignore the Zone Status.Accepted values: 0 through 5 seconds, in steps of 1 second.Default setting: 2 seconds. User CodeThe 4-digit User Code will allow access to Level 2 of theControl panel.Default setting: 1234Figure 26 The Settings page42 Conventional Fire Panels J424/J408

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!