3-27 ENGINE▣ CAMSHAFT JOURNAL WEARDetermine whether or not each journal is worn downto the limit by measuring the oil clearance with thecamshaft installed in place.● Use the plastigauge to read the clearance at thewidest portion, which is specified as follows :Camshaft journaloil clearance(IN & EX)Service limit0.15 mm (0.006 in)If the camshaft journal oil clearance exceeds the <strong>service</strong>limit, measure the inside diameter of thecamshaft housing and outside diameter of thecamshaft journal. Replace the camshaft or the cylinderhead and camshaft housing depending uponwhich one exceeds the specification.Camshaft housing I.DIN.EX.Standard22.012 ~ 22.025 mm(0.8666 ~ 0.8671 in)Small bore gauge : 09900-22401Camshaft O.DIN.EX.Standard21.959 ~ 21.980 mm(0.8645 ~ 0.8654 in)Micrometer(0 ~ 25 mm) : 09900-20201▣ CAMSHAFT RUNOUTSupport the valve using a V-blocks and measure thecamshaft runout using the dial gauge. If the runoutexceeds the <strong>service</strong> limit, replace the camshaft with anew one.Camshaft runoutService limit0.10 mm (0.004 in)Dial gauge : 09900-20606Magnetic stand : 09900-20701V-block : 09900-21304