13.07.2015 Views

warning - Docs.hvacpartners.com

warning - Docs.hvacpartners.com

warning - Docs.hvacpartners.com

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

STARTIs LED status light on?YESIs LED status light blinking rapidly withouta pause?NOIs LED status light blinking ON/OFFslowly with a <strong>com</strong>bination of short andlong flashes?YESDetermine status code. The status codeis a 2 digit number with the first digitdetermined by the number of shortflashes and the second digit by thenumber of long flashes?Go to section below for the status codethat was flashed.NOYESNOYES59TP5ATroubleshooting GuideNONOIs there 115V at L1 and L2?Is door switch closed?Is door switch closed?YESYESNONOIs there 24V at SEC-1 and SEC-2?Is there 115V going to switch?Is circuit breaker closed?YES YES YESReplace furnace control.Replace door switch.Check for continuity in wire from circuitbreaker to furnace.Check for correct line voltage polarity. Ifunits are twinned, check for proper lowvoltage(24V) transformer phasing.Replace transformer.Close circuit breaker and go back toSTART.To recall status code briefly remove and reconnect one RED wire from the draftsafeguard switch to display stored status code. You can also recall the previousstatus code by momentarily shorting the TEST/TWIN terminal to Com24V terminaluntil the LED goes out. LED will flash the status code of the previous fault or statuscode #11 (1 short and 1 long flash) if there was no previous fault. After the controlrepeats the code 4 times, the control will start the <strong>com</strong>ponent test sequence. Onceinitiated the control will turn the inducer ON at high-heat speed. The inducer will runfor the entire <strong>com</strong>ponent test. The HSI, blower motor LO HEAT speed, HI HEATspeed, and COOL speed will run for 10 – 15 seconds each. Gas valve andhumidifier will not be turned on. When the blower motor is turned OFF the inducerwill be switched to low-speed for 10 seconds.Check room thermostat orinterconnecting cable.NOWas there a previous status code otherthan #11?NODoes the control respond to W/W1, W2,Y1, Y/Y2, and G (24V) thermostatsignals?NOIs 24V present at W/W1, W2, Y1, Y/Y2 orG thermostat terminals on the furnacecontrol?YESYESRun system through a low-heat, highheat,or cooling cycle to check operation.Status codes are erased after 72 hours.Disconnect all the thermostat wires fromthe furnace control.Replace furnace control.YESDoes the problem repeat when using ajumper wire?NOThe thermostat is not <strong>com</strong>patible with thefurnace control. Either install a ballastresistor, connect the Com24V thermostatterminal to the thermostat, or replace thethermostat.NOFig. 62 - Troubleshooting GuideA11323A80

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!