• ClearEventCounterDescription:This function is used to clear the value of event counter of I-7000 series modules. Thisfunction only supports I-7011, I-7012, I-7014 and I-7016 modules.Syntax:[ C ]WORD ClearEventCounter(WORD wBuf[], float fBuf[], char szSend[],char szReceive[])Parameter:wBuf: WORD Input/Output argument talbewBuf[0] : [Input] COM port number, from 1 to 255wBuf[1] : [Input] Module address, form 0x00 to 0xFFwBuf[2] : [Input] Module ID, 0x7011/12/14/16wBuf[3] : [Input] 0= Checksum disable; 1= Checksum enablewBuf[4] : [Input] Timeout setting , normal=100 msecondwBuf[5] : : Not usedwBuf[6] : [Input] 0 no save to szSend &szReceive1 Save to szSend &szReceivefBuf : Not used.szSend : [Input] Command string to be sent to I-7000 series modules.szReceive : [Output] Result string receiving from I-7000 series modules .Return Value:0 is for SuccessNot 0 is for FailureExample:char szSend[80];char szReceive[80];float fBuf[12];WORD wBuf[12];WORD m_port=3;WORD m_address=1;WORD m_timeout=100;WORD m_checksum=0;Open_Com(COM3, 9600, Data8Bit, NonParity, OneStopBit);LinPAC-8x4x SDK:100