20.07.2015 Views

Installation Manual - Fireplaces

Installation Manual - Fireplaces

Installation Manual - Fireplaces

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

28 <strong>Installation</strong> (for qualified installers only)Rear Vent Configuration with Horizontal Termination (with vertical rise)• The termination must fall within the shaded area shown in the chart. Use the indicated restrictor anddiffuser positions.• Up to four elbows (45° or 90°) may be used.• Only one horizontal elbow may be used.0 feet5 feet (1.5 m)10 feet (3 m)15 feet (4.5 m)20' max (6 m)22' max (6.7 m)15 feet (4.5 m)10 feet (3 m)5 feet (1.5 m)Exhaust Restrictor # 5Intake Restrictor # 2Diffuser Position # 2Exhaust Restrictor # 4Intake Restrictor # 2Diffuser Position # 2Exhaust Restrictor # 2Intake Restrictor # 1 (stock)Diffuser Position # 1 (stock)22' max (6.7 m)20 feet (6 m) 20 feet (6 m)15 feet (4.5 m)10 feet (3 m)5 feet (1.5 m)0 feet0 feet0 feet5 feet (1.5 m)10 feet (3 m)15 feet (4.5 m)20' max (6 m)H2This is considered a horizontalelbow (it does not matterwhether it turns right or left).It may be a 90° or 45° elbow.Horizontal length is calculated by addingboth lengths of horizontal run(Horizontal Length = H1 + H2).H1This is considered avertical elbowTravis Industries 4081126 100-01210_000

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!