Mantel RequirementsCombustible Mantels<strong>Installation</strong> (for qualified installers only) 41• Use the table below to determine the maximum mantel depth allowed. The mantel depth (measuredfrom the face of the fireplace) must fall in the shaded portion of the table.• Any material that protrudes more than 3/4” (19mm) from the non-combustible facing is considered amantel and must meet the mantel requirements.Combustible MantelMaximum Mantel Depth (b)ab39"+(991mm+)38"(965mm)37"(940mm)36"(914mm)Mantel Height35"(889mm)Above Base ofFireplace (a) 34"(864mm)33"(838mm)32"(813mm)31"(787mm)30"(762mm)0"3" (76mm)4" (102mm)5" (127mm)1" (25mm)2" (51mm)6" (152mm)7" (178mm)8" (203mm)9" (229mm)10" (254mm)11" (279mm)12" (305mm)30-1/4"768mmTop of Fireplace(not stand-off)NOTE: No combustibles may beinstalled in front of fireplace.Combustible mantel columns (legs) that protrude more than 3/4" (0.75mm) from the glass frame mustmeet the 1" (25mm) sidewall clearance. If they protrude 3/4" (0.75mm) or less, they may be placeddirectly to the side (but not in front) of the fireplace.Non-combustible mantel columns do not have a minimum clearance.Examples:- If you wish to have a 6” (152mm) deep mantel, it must be at least 37” (940mm) above the base of the fireplace.- If you wish to have a 2” (51mm) deep breastplate, it must be at least 36” (914mm) above the base of the fireplace.Non-Combustible MantelsNon-combustible mantels must meet the clearances listed for combustible mantels. However, if you dowish to reduce the clearances by using a non-combustible mantel, the following requirements must be met:• Non-combustible manteland facing must extendfrom the top of theappliance to the topsurface of the mantel.• A non-combustibleheader must be used(metal stud).Non-Combustible Framing (metal studs)must be used for the header.SIDE OF FIREPLACEDrywallNon-Combustible MantelNon-Combustible Facing© Travis Industries 4081126 100-01210_000

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!