cadera / hip - Active Congress.......
cadera / hip - Active Congress.......
cadera / hip - Active Congress.......
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
MARTES / TUESDAY<br />
64<br />
arthro;lasty complicated by a malignat<br />
fi brous histiocytoma. A case report. J<br />
Arthroplasty. 1992;7:549-550.<br />
191. Streicher R, Schon R, Semlitsch MF:<br />
Moglichkeiten der Opimierung von Gleitpaarungen<br />
gegen ultrahochmolekulares<br />
Polyethylen fur Kunstliche Gelenke.<br />
Biomed. Technik, Band 35, 1990, p 78<br />
192. Streicher RM: Infl uence of ionizing irradiation<br />
in air and nitrogen for sterilization<br />
of surgical grade polyethylene for implants.<br />
Radiat Phys Chem 188;31:693-698.<br />
193. Sun DC, Schmidig G, Stark C, Dubleton<br />
JH: Free radicals in irradiated UHMWPE<br />
are “visible”. Proceedings of the Society<br />
for Biomaterials 24th Annual Meeting, San<br />
Diego, CA, 1998.<br />
194. Sutula LC, Collier JP, Saum KA, Currier<br />
BHY, Currier JH, Sanford WM, Mayor<br />
MB, Wooding RE, Sperling DK, Williams<br />
IR, Kasprzak DJ, Suprenant VA: Impact<br />
of gamma sterilization on clinical performance<br />
of polyethylene in the <strong>hip</strong>. Clin<br />
Orthrop 1995;319:28-40.<br />
195. Swann M: Malignant soft-tissue tumor at<br />
the site of a total <strong>hip</strong> replacement. J Bone<br />
Joint Surg 1984;66:629-631.<br />
196. Tait NP, Hacking PM, Malcolm AJ: Malignant<br />
fi brous histiocytoma occurring at<br />
the site of a previous total <strong>hip</strong> replacement.<br />
Br J Radio. 1988;61:73-76<br />
197. Tanaka K, Tamura J, Kawanabe K, Shimizu<br />
M, Nakamura T: Effect of alumina<br />
femoral heads on polyethylene wear in<br />
cemented total <strong>hip</strong> arthroplasty. Old versus<br />
current alumina. J Bone Jont Surg Br.<br />
85(5):655-60, 2003.<br />
198. Taylor SK: In-Vitro wear performance of<br />
a contemporary alumina-alumina bearing<br />
couple under anatomically-relevant <strong>hip</strong><br />
joint simulation, Sedel S, Eillmann G (eds):<br />
Reliability and long term results of ceramics<br />
in orthopaedics. Stuttgart, Germany,<br />
Georg Thieme Verlag, 1999, pp 85-90.<br />
199. Tharani R, Dorey FJ, Schmalzried TP:<br />
The risk of cancer following total <strong>hip</strong> or<br />
knee arthroplasty. J Bone Joint Surg.<br />
2001;83A:774-780.<br />
200. Tillberg B: Total <strong>hip</strong> arthroplasty using<br />
the McKee & Watson-Farrar Prosthesis. A<br />
prospective follow-up study of 327 arthroplasties.<br />
Acta Orthop Scand 53:104-107,<br />
1982.<br />
201. Ueno M, Amino H, Okimatu H, Oonishi<br />
H: Wear, friction, and mechanical investigation<br />
and development of alumina-alumina<br />
combination total <strong>hip</strong> joint in Imura<br />
S, Wada M, Omori H (eds): Joint Arthroplasty.<br />
Tokyo, Japan, Springer, 1999k pp<br />
119-131<br />
202. Visuri T, Pukkala E, Paavolainen P, Pulkkinen<br />
P, Riska EB: Cancer risk after metal<br />
on metal and polyethylene on metal total<br />
<strong>hip</strong> arthroplasty. Clin Orthop 1996;329S:<br />
S280-S289.<br />
203. Visuri T: Long tern results and survivors<strong>hip</strong><br />
of the McKee-Farrar total <strong>hip</strong> prosthesis.<br />
Arch Orthopo 106:368-374, 1987<br />
204. Walker PS, Gold BL: The Tribology (friction,<br />
lubrication, and wear) for all-metal<br />
artifi cial joints. Wear 17:285-99, 1971<br />
205. Walsh H, Gillis A, Furman B, Li S:<br />
Factors that determine the oxidation resistance<br />
of molded 1900: Is it the resin<br />
or the molding? Trans Orthop Res Soc<br />
2000; 25:543.<br />
206. Walter A: On the material and the tribology<br />
of alumina-alumina couplings for <strong>hip</strong><br />
joint prostheses. Clin Orthop 1990;282:31-<br />
46.<br />
207. Wan Z, Dorr LD: Natural History of<br />
Femoral focal osteolysis with proximal in<br />
growth smooth stem implant. J Arthroplasty<br />
1996;11:718-725.<br />
208. Wang A, Essner A, Polineni VK, Stark<br />
C, Dumbleton JH: Lubrication and wear<br />
of ultra high molecular weight polyethylene<br />
in total joint replacements. Tribology<br />
1998;31:17-33.<br />
209. Weber PC: Epitheloioid sarcoma in<br />
association with total knee replacement.<br />
A case report. J Bone Joint Surg Br.<br />
1986;68:824-826<br />
210. Willmann G: Ceramics for total <strong>hip</strong> replacement:<br />
What a surgeon should know.<br />
Orthopedics 1998;21:173-177.