Is 4-way valve coil connector<br />

connected?<br />

�<br />

Are connectors of TS, TE, Pd<br />

sensors connected?<br />

�<br />

Are resistance value<br />

characteristics of TS and TE<br />

sensors normal?<br />

Is there a problem on wiring of<br />

fixed-speed compressor?<br />

�<br />

Yes<br />

Yes<br />

Are the output voltage<br />

characteristics of Pd sensor<br />

normal?<br />

Yes<br />

�<br />

Yes<br />

4-way valve error<br />

Troubleshooting<br />

Diagnostic procedure for check code<br />

Check code Operation cause<br />

[08] 1. 4-way valve operation error.<br />

4-way valve reversal alarm 2. TS sensor/TE sensor error.<br />

3. Pd sensor error.<br />

4. Fixed-speed compressor Mg-SW operation error.<br />

Is 4-way valve cool normal?<br />

�<br />

�<br />

Yes<br />

�<br />

Reset power supply and perform<br />

trial heating operation.<br />

�<br />

No<br />

Does 4-way valve operate?<br />

�<br />

Yes<br />

No<br />

Is fixed-speed compressor<br />

activated?<br />

No<br />

No<br />

No<br />

No<br />

No<br />

Yes<br />

Yes<br />

�<br />

No<br />

�<br />

Does refrigerant bypass<br />

from discharge to suction<br />

on 4-way valve?<br />

Yes<br />

Does OL of Mg-SW<br />

operate?<br />

No<br />

�<br />

Does IOL of fixed-speed<br />

compressor operate?<br />

No<br />

No<br />

�<br />

�<br />

�<br />

�<br />

�<br />

�<br />

�<br />

�<br />

Yes<br />

�<br />

Yes<br />

�<br />

�<br />

Modify connector connection<br />

(4-way valve coil: CN 317)<br />

4-way valve cool error<br />

Modify connection of connectors.<br />

TS sensor: PJ3<br />

TE sensor: PJ4<br />

Pd sensor: PJ7<br />

Sensor error<br />

Sensor error<br />

Correct wiring<br />

Restart the operation if a trouble has not<br />

occurred in trial operation.<br />

Check 4-way valve<br />

Restart the operation after manual reset<br />

Restart the operation after compressor<br />

IOL reset (automatic reset)<br />

Mg-SW error