18.12.2012 Views

Super Multi System - Toshiba

Super Multi System - Toshiba

Super Multi System - Toshiba

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Check code Status of air conditioner Operation cause<br />

[1d] Operation stops 1. Outdoor unit power source error.<br />

Compressor error alarm 2. Inverter compressor circuit system error.<br />

Refer to outdoor unit 3. Inverter compressor error.<br />

4. Inverter compressor refrigerant stagnation.<br />

5. Defective IPDU PC board.<br />

44<br />

Is the power source voltage of the<br />

outdoor unit normal?<br />

�<br />

Does voltage reduction occur<br />

when the fixed-speed compressor<br />

has been activated?<br />

�<br />

Is the connection of wiring on<br />

the IPDU PC board normal?<br />

�<br />

Is there an abnormal overload?<br />

�<br />

Is the inverter compressor normal?<br />

�<br />

Is there refrigerant stagnation<br />

in the compressor case?<br />

�<br />

Yes<br />

No<br />

Yes<br />

No<br />

Yes<br />

No<br />

Check IPDU PC board.<br />

Troubleshooting<br />

Diagnostic procedure for check code<br />

No<br />

Yes<br />

No<br />

Yes<br />

No<br />

Yes<br />

Yes<br />

Is the inverter winding<br />

� �<br />

output normal?<br />

�<br />

No<br />

�<br />

Check IPDU PC board.<br />

�<br />

�<br />

�<br />

�<br />

Confirm the power source supply.<br />

Modify connector wiring.<br />

Modify cause of overload.<br />

Compressor error<br />

Modify refrigerant stagnation in<br />

the compressor case, and start<br />

the operation.