Check code Operation cause<br />

[21] 1. Inverter high pressure SW error.<br />

Inverter high pressure SW system alarm 2. Inverter IOL operation.<br />

3. Service valve closed.<br />

4. Outdoor fan, capacitor error.<br />

5. Indoor/Outdoor PMV blockage.<br />

6. Outdoor heat exchanger blockage.<br />

7. SV2 circuit blockage.<br />

8. Indoor – Outdoor communication error.<br />

9. Pd sensor error.<br />

10.Refrigerant overcharge.<br />

46<br />

Does the inverter high pressure<br />

switch operate?<br />

�<br />

Are the inverter high pressure<br />

switch parts normal?<br />

�<br />

Is service valve fully open?<br />

�<br />

Does the cooling outdoor fan<br />

normally operate?<br />

�<br />

Is there a problem with the<br />

outdoor unit heat exchanger?<br />

(1) Blockage of heat exchanger<br />

(2) Short circuit<br />

Il circuito di bypass della � SV2 è normale?<br />

Is SV2 bypass circuit normal?<br />

�<br />

A<br />

Yes<br />

Yes<br />

Yes<br />

Yes<br />

No<br />

Yes<br />

�<br />

Check parts.<br />

If defective, replace.<br />

Open service valve fully.<br />

No<br />

No<br />

No<br />

No<br />

�<br />

Yes<br />

�<br />

Remove cause.<br />

No<br />

Troubleshooting<br />

Diagnostic procedure for check code<br />

�<br />

Repair SV2 bypass circuit.<br />

�<br />

Are the connection, capacitor<br />

and fan motor normal?<br />

�<br />

Are the high pressure sensor<br />

characteristics normal?<br />

�<br />

Yes<br />

Yes<br />

�<br />

See judgment flow of IPDU IOL<br />

operation circuit “E5”.<br />

�<br />

Check and modify wiring<br />

No<br />

�<br />

Repair defective position.<br />

No<br />

No<br />

�<br />

No<br />

Replace high pressure sensor.<br />

Check outdoor IPDU PC board.<br />

If defective, replace board.<br />

(Coil error, disconnection of wiring, etc.)<br />

�<br />

Is the inverter IOL<br />

circuit normal?<br />

�<br />

Is circuit wiring normal?<br />

�<br />

Yes<br />

Yes