2. Define or alter your existing catalogs with the attribute ECSHARING using the IDCAMS<br />

DEFINE or ALTER commands.<br />

The ECSHARING attribute makes a catalog eligible for sharing using the ECS protocol,<br />

as opposed to the VVDS/VVR protocol. The catalog can still be used in VVDS mode.<br />

3. Activate all eligible catalogs for ECS sharing.<br />

You can use the command MODIFY CATALOG,ECSHR(AUTOADD) on one system to activate all<br />

ECS-eligible catalogs throughout the sysplex for ECS sharing. They are automatically<br />

activated at their next reference. You can manually add a catalog to use ECS by running<br />

the command MODIFY CATALOG,ECSHR(ENABLE,catname) where catname is the name <strong>of</strong> the<br />

catalog you want to add.<br />

Only catalogs that were added are shared in ECS mode. The command MODIFY<br />

CATALOG,ECSHR(STATUS) shows you the ECS status for each catalog, as well as whether it is<br />

eligible and already activated.<br />

Restrictions for ECS mode usage<br />

The following restrictions apply to ECS mode usage:<br />

► You cannot use ECS mode from one system and VVDS mode from another system<br />

simultaneously to share a catalog. You will get an error message if you try this.<br />

Important: If you attempt to use a catalog that is currently ECS-active from a system<br />

outside the sysplex, the request might break the catalog.<br />

► No more than 1024 catalogs can currently be shared using ECS from a single system.<br />

► All systems sharing the catalog in ECS mode must have connectivity to the same<br />

Coupling Facility, and must be in the same global resource serialization (GRS) complex.<br />

► When you use catalogs in ECS mode, convert the resource SYSIGGV2 to a SYSTEMS<br />

enqueue. Otherwise, the catalogs in ECS mode will be damaged.<br />

For more information about ECS, see z/<strong>OS</strong> DFSMS: Managing Catalogs, SC26-7409. For<br />

information about defining Coupling Facility structures, see z/<strong>OS</strong> MVS Setting Up a Sysplex,<br />

SA22-7625.<br />