Planning Guide<br />

Anticipated noise levels for In-line and monobloc pumps<br />

(Orientation values)<br />

Motor power<br />

P N [kW]<br />

Sound-pressure level pA (dB) 1)<br />

Pump with motor<br />

1450 rpm 2900 rpm<br />

< 0.55 52 55<br />

000.75 53 58<br />

001.1 54 58<br />

001.5 54 61<br />

002.2 57 62<br />

003.0 58 64<br />

004.0 58 67<br />

005.5 63 70<br />

007.5 64 71<br />

011.0 67 74<br />

015.0 68 75<br />

018.5 67 76<br />

022.0 67 77<br />

030.0 69 78<br />

037.0 68 74<br />

045.0 68 74<br />

055.0 68 78<br />

075.0 70 80<br />

090.0 70 80<br />

110.0 72 82<br />

132.0 72 82<br />

160.0 72 82<br />

1) Spatial mean value of sound pressure level on a square plate a distance of<br />

1 m from the surface of the motor<br />

Electrical pump drives<br />

The rated power data and operating values for the electrical drives<br />

presented in this catalogue for glanded pumps (Inline and monobloc)<br />

apply at a rated frequency of 50 Hz, a rated voltage of 230 / 400 V to<br />

3 kW or 400 / 690 V starting at 4 kW, a maximum coolant temperature<br />

(KT) of 40°C and an installation altitude of up to 1000 m above<br />

mean sea level.<br />

For cases outside of these parameters a power rating reduction must<br />

be applied or a larger motor or a higher insulation class must be<br />

selected.<br />

All Wilo glanded pumps are fitted as standard with electric motors,<br />

which satisfy the IEC standard in terms of power and design. A<br />

restriction only applies where, due to the design of the pump, coupling<br />

to a standard motor is not possible. In this case motors with an<br />

extended shaft are used.<br />

The customary motor speed categories / operating speeds are as follows:<br />

No. of poles 50 Hz 60 Hz<br />

2 2900 rpm 3500 rpm<br />

4 1450 rpm 1750 rpm<br />

6 960 rpm 1150 rpm<br />

High-efficiency motor<br />

From a motor power of 1.1 kW Wilo glanded pumps can be supplied<br />

to order with EFF1 high efficiency motors.<br />

Application of explosion-protected pumps to directive<br />

94/9/EG (ATEX100a)<br />

Areas made hazardous by the risk of explosion are those, in which an<br />

explosion-supporting atmosphere (gas / dust) can occur in sufficient<br />

measure to present a risk.<br />

These areas are divided into zones. Decisions on the assignment of<br />

zones lie with the operator and the respective regulation authority.<br />

The testing of pumps (machines) and hence the approval for use in<br />

hazardous areas is governed in the EU on the basis of the relevant<br />

explosion protection specification 94 / 9 / EG (ATEX100a) by appropriate<br />

authorised test organisations. Approval is granted by means of<br />

a prototype test certificate. Wilo glanded pumps of Series IL, DL, BL,<br />

IPL (only variant –N), DPL (only variant -N), IPS and IPH can be supplied<br />

with the appropriate approvals for use in potentially explosive<br />

areas.<br />

These pumps have a prototype test certificate in accordance with<br />

directive 94 / 9 / EG (ATEX100a), which permits the following designations<br />

to be applied:<br />

II 2 G c b II A T3, T4 / II 2 G c b II C T3, T4<br />

CE = CE Symbol<br />

II = Equipment group<br />

G = Ex-Atmospheres due to gases, vapours and mist<br />

c = Design safety (Protection due to safe construction)<br />

b = Ignition source monitoring with T4<br />

T1-T4 = Temperature Class with maximum surface temperature<br />

T1 = 450°C<br />

T2 = 300°C<br />

T3 = 200°C<br />

T4 = 135°C<br />

e / d = Ignition protection category of the motor<br />

e = increased safety<br />

d = pressure-resistant enclosure<br />

Particular attention must be paid to ensure that for applications in<br />

the temperature range T4 the pumps and mechanical seals are additionally<br />

protected against dry running.<br />

10 Subject to change without prior notice 09/2006 WILO AG