Switching and Control Devices<br />
Wilo-CRn- and CR control devices<br />
Technical Data Wilo-CRn, Wilo-CR<br />
Switchgear and control functions with Wilo-CR / CRn Systems<br />
Switchgear and control functions local and / or internal<br />
- Mains – 0 – Auto manual switchover<br />
- Fault-actuated switchover from ‘frequency converter’ to ‘mains’<br />
- Fault-actuated switchover from main to standby pump<br />
- Peak-load cut-in for differential pressure p, pressure p<br />
- or differential temperature T<br />
- Collective run / fault signals For connection details, see Terminal diagram,<br />
CR / CRn System base board<br />
-Pump alteration every 24 hours<br />
- Time-sensitive switchover to minimum speed or second controlled<br />
level<br />
Switchgear and control functions available for remote control<br />
- Remote setpoint adjustment 0 / 2 – 10 V or 0 / 4 – 20 mA<br />
(For connection details, see Terminal diagram CR / CRn System base<br />
board)<br />
- Overriding On / Off control by switch provided by customer<br />
(For connection details, see Terminal diagram CR / CRn System base<br />
board)<br />
- Standby control operation with test run every 24 hours<br />
with auxiliary DDC board<br />
(For connection details, see Terminal diagram DDC board)<br />
- Night setback to Minimum speed or second controlled level<br />
- Peak-duty pump(s) cut-in and pump duty cycling<br />
- Switchover to manual control mode<br />
- Remote speed adjustment<br />
- Remote confirmation of collective fault signal<br />
Accessories for Wilo-CR / CRn Systems<br />
Accessories<br />
Wilo Catalogue A2 - <strong>Glanded</strong> pumps<br />
with auxiliary control board<br />
(For connection details, see Terminal diagram control board)<br />
- Mains / Automatic operating mode switchover<br />
- Isolating individual pumps for repairs<br />
Control functions for Wilo-CR / CRn Systems<br />
Control functions for single-head pumps and multi-pump systems<br />
(heating / air-conditioning)<br />
Flow volume constant Q-c<br />
- Differential temperature variable T-v<br />
- Differential pressure constant p-c<br />
- Differential temperature T<br />
- Differential pressure, delivery-superimposed p-q<br />
- T outdoor-temperature-superimposed T-T A<br />
- Differential pressure, temperature-superimposed p-T<br />
- Manual control mode DDC<br />
Control functions for single-head pumps<br />
(heating / air-conditioning)<br />
- Differential pressure variable p-v<br />
- Process temperature ±T<br />
Control functions for single-head pumps and multi-pump systems<br />
(pressure boosting)<br />
- Constant pressure p-c<br />
- Flow volume constant Q-c<br />
- Flow volume constant Q-c<br />
Sensor / transmitter Differential pressure sensor DDG (4 – 20 mA) (observe measuring range)<br />
Outdoor temperature sensor KTY or PT 100<br />
Terminal diagram:<br />
Base board CR / CRn System<br />
Temperature board<br />
Automatic, stepless speed<br />
control as a function of feed<br />
or return temperature or as a<br />
function of the difference<br />
between feed and return<br />
temperatures<br />
Control board<br />
DDC board<br />
Signal board 1 – 2<br />
Signal board 3 – 6<br />
TSG temperature signal transmitter (included in the scope of delivery of the<br />
temperature board)<br />
Temperature board KTY 10:<br />
Heating systems with big differentials (T max: +140°C, T min 10 K,<br />
T max: 100 K), 2 temperature transmitter TSG included in scope of delivery<br />
Temperature board PT 100:<br />
Cooling / air-conditioning systems with small differentials (T max: +140°C,<br />
T min 5 K, T max: 100 K)<br />
Shutdown of each pump (up to 2 pumps) by repair switch onsite and remote<br />
adjustment of operating mode (Mains / Automatic) for each pump (up to 2 pcs.)<br />
3 control boards are required for 6 pumps<br />
Load adjustment of the pump system (setpoint-actual value comparison) by<br />
external controller, pump activation and deactivation, pump duty cycling, setpoint<br />
switchover, switchover to manual control mode and confirmation of the<br />
collective fault signal by external potential-free contact<br />
Potential-free individual operation / Individual fault signal for the pumps 1 – 2<br />
and frequency converter, status signals to the digital inputs DIG2 or DIG3 (e.g.<br />
low water, antifreeze protection), speed-actual value or transmitter-actual<br />
value (can be preselected)<br />
Terminal diagram:<br />
KTY 10 temperature board<br />
Terminal diagram:<br />
KTY 10 temperature board<br />
Terminal diagram:<br />
PT 100 temperature board<br />
Terminal diagram:<br />
Control board<br />
Terminal diagram:<br />
DDC board<br />
Terminal diagram:<br />
Signal board 1-2<br />
Potential-free individual operation / Individual fault signal for the pumps 3 – 6 Terminal diagram:<br />
Signal board 3-6<br />
189<br />