Switching and Control Devices<br />

Wilo-CRn- and CR control devices<br />

Technical Data Wilo-CRn, Wilo-CR<br />

Switchgear and control functions with Wilo-CR / CRn Systems<br />

Switchgear and control functions local and / or internal<br />

- Mains – 0 – Auto manual switchover<br />

- Fault-actuated switchover from ‘frequency converter’ to ‘mains’<br />

- Fault-actuated switchover from main to standby pump<br />

- Peak-load cut-in for differential pressure p, pressure p<br />

- or differential temperature T<br />

- Collective run / fault signals For connection details, see Terminal diagram,<br />

CR / CRn System base board<br />

-Pump alteration every 24 hours<br />

- Time-sensitive switchover to minimum speed or second controlled<br />

level<br />

Switchgear and control functions available for remote control<br />

- Remote setpoint adjustment 0 / 2 – 10 V or 0 / 4 – 20 mA<br />

(For connection details, see Terminal diagram CR / CRn System base<br />

board)<br />

- Overriding On / Off control by switch provided by customer<br />

(For connection details, see Terminal diagram CR / CRn System base<br />

board)<br />

- Standby control operation with test run every 24 hours<br />

with auxiliary DDC board<br />

(For connection details, see Terminal diagram DDC board)<br />

- Night setback to Minimum speed or second controlled level<br />

- Peak-duty pump(s) cut-in and pump duty cycling<br />

- Switchover to manual control mode<br />

- Remote speed adjustment<br />

- Remote confirmation of collective fault signal<br />

Accessories for Wilo-CR / CRn Systems<br />

Accessories<br />

Wilo Catalogue A2 - <strong>Glanded</strong> pumps<br />

with auxiliary control board<br />

(For connection details, see Terminal diagram control board)<br />

- Mains / Automatic operating mode switchover<br />

- Isolating individual pumps for repairs<br />

Control functions for Wilo-CR / CRn Systems<br />

Control functions for single-head pumps and multi-pump systems<br />

(heating / air-conditioning)<br />

Flow volume constant Q-c<br />

- Differential temperature variable T-v<br />

- Differential pressure constant p-c<br />

- Differential temperature T<br />

- Differential pressure, delivery-superimposed p-q<br />

- T outdoor-temperature-superimposed T-T A<br />

- Differential pressure, temperature-superimposed p-T<br />

- Manual control mode DDC<br />

Control functions for single-head pumps<br />

(heating / air-conditioning)<br />

- Differential pressure variable p-v<br />

- Process temperature ±T<br />

Control functions for single-head pumps and multi-pump systems<br />

(pressure boosting)<br />

- Constant pressure p-c<br />

- Flow volume constant Q-c<br />

- Flow volume constant Q-c<br />

Sensor / transmitter Differential pressure sensor DDG (4 – 20 mA) (observe measuring range)<br />

Outdoor temperature sensor KTY or PT 100<br />

Terminal diagram:<br />

Base board CR / CRn System<br />

Temperature board<br />

Automatic, stepless speed<br />

control as a function of feed<br />

or return temperature or as a<br />

function of the difference<br />

between feed and return<br />

temperatures<br />

Control board<br />

DDC board<br />

Signal board 1 – 2<br />

Signal board 3 – 6<br />

TSG temperature signal transmitter (included in the scope of delivery of the<br />

temperature board)<br />

Temperature board KTY 10:<br />

Heating systems with big differentials (T max: +140°C, T min 10 K,<br />

T max: 100 K), 2 temperature transmitter TSG included in scope of delivery<br />

Temperature board PT 100:<br />

Cooling / air-conditioning systems with small differentials (T max: +140°C,<br />

T min 5 K, T max: 100 K)<br />

Shutdown of each pump (up to 2 pumps) by repair switch onsite and remote<br />

adjustment of operating mode (Mains / Automatic) for each pump (up to 2 pcs.)<br />

3 control boards are required for 6 pumps<br />

Load adjustment of the pump system (setpoint-actual value comparison) by<br />

external controller, pump activation and deactivation, pump duty cycling, setpoint<br />

switchover, switchover to manual control mode and confirmation of the<br />

collective fault signal by external potential-free contact<br />

Potential-free individual operation / Individual fault signal for the pumps 1 – 2<br />

and frequency converter, status signals to the digital inputs DIG2 or DIG3 (e.g.<br />

low water, antifreeze protection), speed-actual value or transmitter-actual<br />

value (can be preselected)<br />

Terminal diagram:<br />

KTY 10 temperature board<br />

Terminal diagram:<br />

KTY 10 temperature board<br />

Terminal diagram:<br />

PT 100 temperature board<br />

Terminal diagram:<br />

Control board<br />

Terminal diagram:<br />

DDC board<br />

Terminal diagram:<br />

Signal board 1-2<br />

Potential-free individual operation / Individual fault signal for the pumps 3 – 6 Terminal diagram:<br />

Signal board 3-6<br />

189<br />

Planning Guide<br />

Energy-saving pumps<br />

Standard pumps<br />

Special In-line <strong>Pumps</strong><br />

Switching and Control Devices<br />

Pump Management Systems