Glanded Pumps - THERMO-ECO-ENGINEERING úvod
Glanded Pumps - THERMO-ECO-ENGINEERING úvod
Glanded Pumps - THERMO-ECO-ENGINEERING úvod
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Standard <strong>Pumps</strong><br />
Twin-head pumps (Heating, Air-conditioning, Cooling and Industry)<br />
Terminal diagram, Motor Data Wilo-CronoTwin-DL<br />
Terminal Diagrams<br />
Star activation Y Delta activation <br />
W2 U2 V2<br />
U1 V1 W1<br />
L 2 L 1 L3 PE<br />
L 2 L 1 L3<br />
Motor Data (1450 rpm)<br />
Wilo-CronoTwin-DL<br />
...<br />
W2 U2 V2<br />
U1 V1 W1<br />
PE<br />
Motor protection switch required onsite. Check direction of rotation.<br />
To change the direction of rotation, swap any two phases.<br />
P2 3 kW 3~400 V Y<br />
3~230 V <br />
P2 4 kW 3~690 V Y<br />
3~400 V <br />
After removing the bridge Y--starting is possible.<br />
Nominal current (approximately) Power factor Efficiency<br />
IN 3~400 V cos M [A] –<br />
0.25 kW 0.77 0.78 0.60<br />
0.37 kW 1.06 0.78 0.65<br />
0.55 kW 1.44 0.82 0.67<br />
0.75 kW 1.91 0.81 0.72<br />
1.10 kW 2.55 0.81 0.77<br />
1.50 kW 3.40 0.81 0.79<br />
2.20 kW 4.70 0.82 0.82<br />
3.00 kW 6.40 0.82 0.83<br />
4.00 kW 8.20 0.83 0.85<br />
5.50 kW 11.40 0.81 0.86<br />
7.50 kW 15.20 0.82 0.87<br />
11.00 kW 21.50 0.84 0.89<br />
15.00 kW 28.50 0.84 0.90<br />
18.50 kW 35.50 0.83 0.91<br />
22.00 kW 41.50 0.84 0.91<br />
30.00 kW 55.00 0.86 0.92<br />
37.00 kW 66.00 0.87 0.93<br />
45.00 kW 80.00 0.87 0.93<br />
55.00 kW 100.00 0.85 0.94<br />
Note motor type label data!<br />
Motor Data (2900 rpm)<br />
Wilo-CronoTwin-DL<br />
...<br />
Nominal current (approximately) Power factor Efficiency<br />
IN 3~400 V cos M [A] –<br />
1.50 kW 3.25 0.85 0.79<br />
2.20 kW 4.55 0.85 0.82<br />
3.00 kW 6.10 0.85 0.84<br />
4.00 kW 7.80 0.86 0.86<br />
5.50 kW 10.40 0.89 0.87<br />
142 Subject to change without prior notice 09 / 2006 WILO AG