18.01.2013 Views

Glanded Pumps - THERMO-ECO-ENGINEERING úvod

Glanded Pumps - THERMO-ECO-ENGINEERING úvod

Glanded Pumps - THERMO-ECO-ENGINEERING úvod

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Switching and Control Devices<br />

Wilo-VR, CRn, and CR control devices<br />

Performance features<br />

Equipment features (Continued)<br />

“Mains – Emergency – Operation”<br />

service selector switch for maintenance<br />

purposes<br />

Night setback to minimum speed<br />

or second controlled level by<br />

internal time switch<br />

Remote confirmation of collective<br />

fault signal<br />

Wilo Catalogue A2 - <strong>Glanded</strong> pumps<br />

– • •<br />

– • •<br />

– •<br />

(with DDC board)<br />

•<br />

(with DDC board)<br />

Pilot pump function – • •<br />

Time switch – • •<br />

Switchover to a second setpoint<br />

level<br />

Individual run and fault signals for<br />

pumps and converters<br />

Manual- / Automatic-switchover<br />

with external switch<br />

Connection option for a repair<br />

switch (potential-free contact)<br />

– •<br />

(with DDC board)<br />

•<br />

(with Options board)<br />

•<br />

(with signal board)<br />

– •<br />

(with control board)<br />

– •<br />

(with control board)<br />

•<br />

(with DDC board)<br />

•<br />

(with signal board)<br />

•<br />

(with control board)<br />

•<br />

(with control board)<br />

more prepared (RS 232) – –<br />

Accessories<br />

DDG differential-pressure sensor • • •<br />

KTY temperature boards / PT100 – • •<br />

TSG temperature sensors – • •<br />

KTY outdoor temperature sensors – • •<br />

PT 100 outdoor temperature<br />

sensors<br />

– –<br />

(to be provided by the customer)<br />

–<br />

(to be provided by the customer)<br />

PTC fault trip – • •<br />

Control board – • •<br />

• •<br />

Signal board •<br />

(Options board)<br />

DDC board – • •<br />

Volumetric-flow transmitter<br />

(onsite)<br />

Special features<br />

DPM<br />

(twin-head pump management)<br />

• = available, – = not available<br />

– • •<br />

for DPM not required<br />

on the following series:<br />

Stratos-D / -Z / -ZD,<br />

TOP-E / -ED,<br />

VeroLine-IP-E, VeroTwin-DP-E,<br />

CronoLine-IL-E and<br />

CronoTwin-DL-E<br />

Wilo Control Device…<br />

VR-HVAC CRn CR<br />

for DPM not required<br />

on the following series:<br />

Stratos-D / -Z / -ZD,<br />

TOP-E / -ED,<br />

VeroLine-IP-E, VeroTwin-DP-E,<br />

CronoLine-IL-E and<br />

CronoTwin-DL-E<br />

•<br />

173<br />

Planning Guide<br />

Energy-saving pumps<br />

Standard pumps<br />

Special In-line <strong>Pumps</strong><br />

Switching and Control Devices<br />

Pump Management Systems

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!