Switching and Control Devices<br />

Wilo-VR, CRn, and CR control devices<br />

Performance features<br />

Control and signalling functions<br />

Remote speed adjustment<br />

(control input)<br />

Remote setpoint adjustment<br />

–<br />

–<br />

0/2- 10 V<br />

0/4- 20 mA<br />

0/2- 10 V<br />

0/4- 20 mA<br />

0 / 2- 10 V<br />

0/4- 20 mA<br />

0/2- 10 V<br />

0/4- 20 mA<br />

Run and fault signal lights • • •<br />

Control input<br />

“Setpoint switchover”<br />

– • •<br />

Control input “Overriding Off” • • •<br />

SBM • • •<br />

SSM • • •<br />

Fault-actuated switchover from<br />

frequency converter to mains<br />

operation<br />

Fault-actuated switchover from<br />

main to standby pump<br />

Status display for pumps and<br />

frequency converters<br />

Equipment features<br />

– – •<br />

• • •<br />

– • •<br />

Motor Protection integrated in pump WSK / SSM, integrated in pump ETA / PTC / WSK<br />

Graphics display Menu navigation / Symbol display Menu navigation / Text display Menu navigation / Text display<br />

User-oriented menu guide with<br />

multi-lingual text display<br />

– • •<br />

Manual Operation Manual / 0 / Auto Manual / 0 / Auto Manual / 0 / Auto<br />

Fault memory 9 messages 35 messages 35 messages<br />

Fault-actuated switchover • • •<br />

Pump kick • • •<br />

Run-time optimisation / Pump<br />

alteration<br />

only time-sensitive pump duty<br />

cycling<br />

• •<br />

Proprietary BUS – – –<br />

RS 485<br />

prepared –<br />

for parameterisation of the<br />

frequency converter<br />

Pump duty splitting up to 4 pumps up to 6 pumps up to 6 pumps<br />

PID controller • • •<br />

Integrated real-time clock with<br />

summer / wintertime switchover<br />

Integrated individual / common<br />

operating hours counter<br />

Run-time optimisation on multipump<br />

systems<br />

Conductivity tests of the actual<br />

value control circuit<br />

• = available, – = not available<br />

Wilo Control Device…<br />

VR-HVAC CRn CR<br />

– • •<br />

• • •<br />

– • •<br />

• • •<br />

172 Subject to change without prior notice 09/2006 WILO AG