Energy-Saving <strong>Pumps</strong><br />

Single-head pumps In-line, double pumps In-line<br />

Equipment / Function<br />

Signal and display functions<br />

Wilo Catalogue A2 - <strong>Glanded</strong> pumps<br />

Wilo-<br />

VeroLine-<br />

IP-E<br />

Wilo-<br />

CronoLine-<br />

IL-E<br />

Wilo-<br />

CronoLine-<br />

IL-E..BF<br />

Wilo-<br />

CronoLine-<br />

IL-E..BF R1<br />

Wilo-<br />

VeroTwin-<br />

DP-E<br />

Wilo-<br />

CronoTwin-<br />

DL-E<br />

Collective fault signal • • • • • •<br />

Collective run signal • • • • • •<br />

Fault light • • • • • •<br />

Fault acknowledgement button • • • • • •<br />

LCD to display pump data and error codes • • – – • •<br />

Data exchange<br />

Infrared interface for wireless data exchange with<br />

IR-Monitor and indicator light<br />

(for functions, cf. IR-Monitor function table)<br />

PLR serial digital interface for connection to BA via<br />

Wilo interface converter or company-specific coupling<br />

modules<br />

Serial digital LON interface for connection to a LON-<br />

WORKS network<br />

• • – – • •<br />

•<br />

with 1 x IF<br />

Module<br />

(Accessory)<br />

•<br />

with 1 x IF<br />

Module<br />

(Accessory)<br />

•<br />

with 1 x IF<br />

Module<br />

(Accessory)<br />

•<br />

with 1 x IF<br />

Module<br />

(Accessory)<br />

Twin-head pump management (twin-head pump or 2 single-head pumps)<br />

Main / standby operation (automatic changeover on<br />

fault / time dependent pump changeover after 24<br />

hours)<br />

Duty / assist mode (Efficiency-optimised peak load<br />

On / Off control)<br />

• = available, – = not available<br />

•<br />

•<br />

•<br />

with 2 x IF<br />

Module<br />

(Accessory)<br />

•<br />

with 2 x IF<br />

Module<br />

(Accessory)<br />

– –<br />

– –<br />

•<br />

with 1 x IF<br />

Module<br />

(Accessory)<br />

•<br />

with 1 x IF<br />

Module<br />

(Accessory)<br />

– – •<br />

– – •<br />

•<br />

with 2 x IF<br />

Module<br />

(Accessory)<br />

•<br />

with 2 x IF<br />

Module<br />

(Accessory)<br />

•<br />

with 2 x IF<br />

Module<br />

(Accessory)<br />

•<br />

with 2 x IF<br />

Module<br />

(Accessory)<br />

21<br />

Planning Guide<br />

Energy-saving pumps<br />

Standard pumps<br />

Special pumps<br />

Switching and Control Devices/<br />

Pump Management Systems