Number of valid observations [%]<br />

Število ustreznih meritev [%]<br />

93,8<br />

99,22<br />

100<br />

100<br />

95,35<br />

100<br />

100<br />

100<br />

93,8<br />

99,22<br />

100<br />

100<br />

95,35<br />

100<br />

100<br />

100<br />

Number of valid observations [%]<br />

Število ustreznih meritev [%]<br />

92,95<br />

100<br />

100<br />

100<br />

66,67<br />

99,36<br />

100<br />

100<br />

92,95<br />

100<br />

100<br />

100<br />

66,67<br />

99,36<br />

100<br />

100<br />

GMX3<br />

100<br />

τ = 3 (99,73%)<br />

τ = 2 (95,45%)<br />

80<br />

τ = 1 (68,27%)<br />

60<br />

40<br />

20<br />

0<br />

K<br />

<br />

2 2<br />

NAS<br />

24 h<br />

SAS<br />

2<br />

1<br />

h<br />

K<br />

<br />

2 2<br />

NAS<br />

24 h<br />

SAS<br />

3<br />

1<br />

h<br />

K<br />

<br />

2 2<br />

SAS<br />

3 24 h<br />

SAS<br />

2<br />

1<br />

h<br />

K<br />

<br />

2 2<br />

SAS<br />

3 24 h<br />

SAS<br />

3<br />

1<br />

h<br />

τ = 1 τ = 2 τ = 3 τ = 4<br />

Figure 4: Results of preformed accuracy comparison for point GMX3 with different t values<br />

GMX4<br />

100<br />

τ = 3 (99,73%)<br />

τ = 2 (95,45%)<br />

80<br />

τ = 1 (68,27%)<br />

60<br />

40<br />

20<br />

0<br />

K<br />

<br />

2 2<br />

NAS<br />

24 h<br />

SAS<br />

2<br />

1<br />

h<br />

K<br />

<br />

2 2<br />

NAS<br />

24 h<br />

SAS<br />

3<br />

1<br />

h<br />

K<br />

<br />

2 2<br />

SAS<br />

3 24 h<br />

SAS<br />

2<br />

1<br />

h<br />

K<br />

<br />

2 2<br />

SAS<br />

3 24 h<br />

SAS<br />

3<br />

1<br />

h<br />

τ = 1 τ = 2 τ = 3 τ = 4<br />

Figure 5: Results of preformed accuracy comparison for point GMX4 with different t values<br />

CONCLUSIONS<br />

Accuracy comparisons were made for all four points that were set up as a part of a monitoring system. For<br />

the comparison of accuracy of points GMX1, GMX3 and GMX4 the law of propagation of variances and co<br />

variances was used. For point GMX2 comparison of accuracy could not be carried out by any of the two<br />

procedures, due to the lack of input data. The accuracy comparisons carried out for point GMX1 have<br />

shown that the observations made in hourly intervals are less precise than those made in daily intervals. The<br />

precision of hourly observations is not sufficient in comparison with daily observations when using the<br />

procedure <br />

SAS 2<br />

for adjustment. The results show that the sufficient match is achieved when using 4 .<br />