Suction pipe cleaning (after every use)<br />

6. Thoroughly clean the suction pipe (27, Fig. F) inside, up<br />

to the suction inlet, with pressurized water.<br />

7. Carefully check the suction pipe gasket (31, Fig. F) for<br />

integrity, and replace it if necessary.<br />

Suction filter cleaning (after every use)<br />

8. Inside the hopper, remove the suction filter fastener (1,<br />

Fig. P).<br />

9. Remove the suction filter (2).<br />

10. Clean the deflector (3, Fig. P) and the fan (4) with<br />

pressurized water. Check that all fan sectors (5) are<br />

clean.<br />

11. Clean the suction filter (2, Fig. Q) with pressurized water<br />

(1).<br />

12. Reinstall the suction filter (2, Fig. P) and secure it with<br />

the retainer (1).<br />

13. Remove the lid support rod (8, Fig. F) and lower the<br />

hopper (12, Fig. G) according to the instructions shown<br />

in the relevant paragraph.<br />

14. Turn off the engine, by turning the ignition key (17, Fig.<br />

D) counterclockwise, to the end of stroke, then remove<br />

it.<br />

Breather filter cleaning (after every use)<br />

15. With a ladder and the help of an assistant, disengage the<br />

fasteners (29, Fig. G) of the breather filter hood (28).<br />

16. Open the hood (1, Fig. R) and install the safety pins (2).<br />

17. Remove the mounting screws (1, Fig. S), then remove<br />

the breather filter (2).<br />

18. Clean the breather filter (2, Fig. T) with pressurized<br />

water (1).<br />

19. Install the breather filter and its hood performing steps<br />

from 15 to 17 in reverse order.<br />

Suction fan bearing automatic grease nipple check<br />

20. Open the left lid (4, Fig. G).<br />

21. Check that the automatic grease nipple (1, Fig. U) is not<br />

running out of grease, then close the left lid (4, Fig. G).<br />

Otherwise fill in the grease nipple, according to the<br />

following procedure.<br />

Suction fan bearing automatic grease nipple filling<br />

22. Close the grease nipple by turning the ring nut (2, Fig. U)<br />

clockwise until the end of stroke.<br />

23. Fill the automatic grease nipple (1, Fig. U) by pumping<br />

the grease with the grease nipple (3).<br />

Use “SKF LGWA2” grease or equivalent.<br />

24. After filling the automatic grease nipple (1, Fig. U), turn<br />

the ring nut (2, Fig. U) counter-clockwise until the mark<br />

"1" is aligned with the notch (4, Fig. U), then stop turning<br />

the ring nut.<br />

25. Close the left lid (4, Fig. G).<br />

USER MANUAL<br />

DUST CONTROL SYSTEM NOZZ<strong>LE</strong> AND<br />

FILTER C<strong>LE</strong>ANING<br />

WARNING!<br />

Protect body parts (eyes, hair, hands, etc.)<br />

properly, when performing cleaning<br />

operations using compressed air or water gun.<br />

Preliminary operations<br />

1. Engage the parking brake (7, Fig. E).<br />

2. Turn the ignition key (17, Fig. D) counterclockwise, to the<br />

end of stroke, then remove it.<br />

Cleaning of nozzles and filters on brooms<br />

3. Unscrew the ring nuts (1, Fig. V).<br />

4. Clean the nozzles (2, Fig. V) and filters (3) with<br />

compressed air. Remove calcium deposits. If necessary,<br />

replace the filters (3).<br />

5. Install the filters and nozzles, and secure them with the<br />

ring nuts. Nozzle holes must be directed down when<br />

tightening.<br />

Cleaning of nozzles and filters in the suction inlet<br />

6. On both sides of the suction inlet (1, Fig. W), remove the<br />

screws (2) together with the nozzles (3) and filters (4).<br />

7. Remove the nozzles (3, Fig. W) from the screws (2),<br />

then remove the filters (4).<br />

8. Clean the nozzles (3, Fig. W), the filters (4) and the<br />

screws (2) with compressed air. Remove calcium<br />

deposits. If necessary, replace the filters (4).<br />

9. Install the filters, nozzles and screws in the reverse order<br />

of removal.<br />

DUST CONTROL SYSTEM WATER FILTER<br />

C<strong>LE</strong>ANING<br />

WARNING!<br />

Protect body parts (eyes, hair, hands, etc.)<br />

properly, when performing cleaning<br />

operations using compressed air or water gun.<br />

NOTE<br />

When the filter is removed, the water inside the<br />

tanks comes out. It is advisable to perform this<br />

maintenance procedure when the tanks are<br />

empty.<br />

1. Turn off the engine, by turning the ignition key (17, Fig.<br />

D) counterclockwise, to the end of stroke, then remove<br />

it.<br />

2. Under the right tank (18, Fig. G), remove the water filter<br />

cover (1, Fig. M) together with the filter (2).<br />

3. Separate the filter (2, Fig. M) from the cover, then wash<br />

and clean it. If necessary, replace the filter.<br />

4. Install the cover (1, Fig. M) and the filter (2).<br />

33014085(3)2006-06 A 21