Suction pipe cleaning (after every use)<br />
6. Thoroughly clean the suction pipe (27, Fig. F) inside, up<br />
to the suction inlet, with pressurized water.<br />
7. Carefully check the suction pipe gasket (31, Fig. F) for<br />
integrity, and replace it if necessary.<br />
Suction filter cleaning (after every use)<br />
8. Inside the hopper, remove the suction filter fastener (1,<br />
Fig. P).<br />
9. Remove the suction filter (2).<br />
10. Clean the deflector (3, Fig. P) and the fan (4) with<br />
pressurized water. Check that all fan sectors (5) are<br />
clean.<br />
11. Clean the suction filter (2, Fig. Q) with pressurized water<br />
(1).<br />
12. Reinstall the suction filter (2, Fig. P) and secure it with<br />
the retainer (1).<br />
13. Remove the lid support rod (8, Fig. F) and lower the<br />
hopper (12, Fig. G) according to the instructions shown<br />
in the relevant paragraph.<br />
14. Turn off the engine, by turning the ignition key (17, Fig.<br />
D) counterclockwise, to the end of stroke, then remove<br />
it.<br />
Breather filter cleaning (after every use)<br />
15. With a ladder and the help of an assistant, disengage the<br />
fasteners (29, Fig. G) of the breather filter hood (28).<br />
16. Open the hood (1, Fig. R) and install the safety pins (2).<br />
17. Remove the mounting screws (1, Fig. S), then remove<br />
the breather filter (2).<br />
18. Clean the breather filter (2, Fig. T) with pressurized<br />
water (1).<br />
19. Install the breather filter and its hood performing steps<br />
from 15 to 17 in reverse order.<br />
Suction fan bearing automatic grease nipple check<br />
20. Open the left lid (4, Fig. G).<br />
21. Check that the automatic grease nipple (1, Fig. U) is not<br />
running out of grease, then close the left lid (4, Fig. G).<br />
Otherwise fill in the grease nipple, according to the<br />
following procedure.<br />
Suction fan bearing automatic grease nipple filling<br />
22. Close the grease nipple by turning the ring nut (2, Fig. U)<br />
clockwise until the end of stroke.<br />
23. Fill the automatic grease nipple (1, Fig. U) by pumping<br />
the grease with the grease nipple (3).<br />
Use “SKF LGWA2” grease or equivalent.<br />
24. After filling the automatic grease nipple (1, Fig. U), turn<br />
the ring nut (2, Fig. U) counter-clockwise until the mark<br />
"1" is aligned with the notch (4, Fig. U), then stop turning<br />
the ring nut.<br />
25. Close the left lid (4, Fig. G).<br />
USER MANUAL<br />
DUST CONTROL SYSTEM NOZZ<strong>LE</strong> AND<br />
FILTER C<strong>LE</strong>ANING<br />
WARNING!<br />
Protect body parts (eyes, hair, hands, etc.)<br />
properly, when performing cleaning<br />
operations using compressed air or water gun.<br />
Preliminary operations<br />
1. Engage the parking brake (7, Fig. E).<br />
2. Turn the ignition key (17, Fig. D) counterclockwise, to the<br />
end of stroke, then remove it.<br />
Cleaning of nozzles and filters on brooms<br />
3. Unscrew the ring nuts (1, Fig. V).<br />
4. Clean the nozzles (2, Fig. V) and filters (3) with<br />
compressed air. Remove calcium deposits. If necessary,<br />
replace the filters (3).<br />
5. Install the filters and nozzles, and secure them with the<br />
ring nuts. Nozzle holes must be directed down when<br />
tightening.<br />
Cleaning of nozzles and filters in the suction inlet<br />
6. On both sides of the suction inlet (1, Fig. W), remove the<br />
screws (2) together with the nozzles (3) and filters (4).<br />
7. Remove the nozzles (3, Fig. W) from the screws (2),<br />
then remove the filters (4).<br />
8. Clean the nozzles (3, Fig. W), the filters (4) and the<br />
screws (2) with compressed air. Remove calcium<br />
deposits. If necessary, replace the filters (4).<br />
9. Install the filters, nozzles and screws in the reverse order<br />
of removal.<br />
DUST CONTROL SYSTEM WATER FILTER<br />
C<strong>LE</strong>ANING<br />
WARNING!<br />
Protect body parts (eyes, hair, hands, etc.)<br />
properly, when performing cleaning<br />
operations using compressed air or water gun.<br />
NOTE<br />
When the filter is removed, the water inside the<br />
tanks comes out. It is advisable to perform this<br />
maintenance procedure when the tanks are<br />
empty.<br />
1. Turn off the engine, by turning the ignition key (17, Fig.<br />
D) counterclockwise, to the end of stroke, then remove<br />
it.<br />
2. Under the right tank (18, Fig. G), remove the water filter<br />
cover (1, Fig. M) together with the filter (2).<br />
3. Separate the filter (2, Fig. M) from the cover, then wash<br />
and clean it. If necessary, replace the filter.<br />
4. Install the cover (1, Fig. M) and the filter (2).<br />
33014085(3)2006-06 A 21