Section Limit defines the chainage where the hot mix asphalt type changes.<br />

Sampling Area defines the section length specifically set aside for sampling both during and after<br />

construction.<br />

Monitoring Portion defines the section length to be used for noise measurement and assessing the<br />

performance <strong>of</strong> the section through visual and other non-destructive methods.<br />

All sections shall be constructed with the same grade asphalt cement used in the remainder <strong>of</strong> the<br />

Contract, outside <strong>of</strong> the test sections. The sequence <strong>of</strong> placement <strong>of</strong> the test sections may be changed,<br />

with the approval <strong>of</strong> the Contract Administrator, to suit field conditions.<br />

The Contractor shall install 300 mm x 300 mm aluminium plate information signs indicating limits<br />

between sections and also limits between monitoring and sampling areas. The Ministry (Provincial Sign<br />

Shop) will supply the signs and the contractor shall pick them up from the address provided below and<br />

haul them to the construction site. The Contractor shall supply 25 mm x 25 mm x 1800 mm steel posts,<br />

and the required bolts. The Contractor shall attach the signs to the steel posts and erect the posts within<br />

the right <strong>of</strong> way at each limit to be confirmed by the Contract Administrator. The Contractor is to advise<br />

the Ministry at least five (5) business days in advance <strong>of</strong> when the signs are required for pick up. The<br />

information signs are available at the following address:<br />

MTO Provincial Sign Shop<br />

Location: 1927 Kipling Avenue, Rexdale, Ontario<br />

Time: 6:30 a.m. – 2:00 p.m. Monday to Friday (except Holidays)<br />

Contact and Phone number: Tracey Johnston 416-314-1898 ext. 303<br />

Quality Assurance<br />

Lot Size and Sampling<br />

Each <strong>of</strong> the binder course and the surface course <strong>of</strong> each test section shall be considered as a single lot<br />

with three sublots (i.e., sampling areas plus monitoring section). Three random sets <strong>of</strong> samples <strong>of</strong> the<br />

mix and three sets <strong>of</strong> compaction cores shall be taken within each sublot. No compaction cores shall be<br />

taken from the Monitoring Portions. Each set <strong>of</strong> samples shall be comprised <strong>of</strong> three samples, one for<br />

QC, one for QA and one for referee testing, as specified elsewhere in the Contract. No compaction<br />

cores shall be taken for OGFC, RAC-O, and HL4 OBC.<br />

The contractor should expect that extra samples from the test sections will be required for research<br />

purposes at no extra cost to the Owner.<br />

Acceptance <strong>of</strong> OGFC<br />

OGFC shall meet the requirements for surface tolerance and visual acceptance as specified elsewhere in<br />

the Contract. Acceptance <strong>of</strong> the material shall be based on the average for the lot meeting the<br />

requirements given in Table C and for air voids, no less than 2 % below the mix design requirements.<br />

No payment adjustment will apply to the mix that meets the criteria. Any sublot that does not meet the<br />