2. Sampling and Analytical Techniques. Integrated waste gas<br />

samples were collected in bags. The analysis was done on a Carle<br />

analytical gas chromatograph having the fol lowing col umns :<br />

1. 6-ft OPN/PORASILR (80/100).<br />

2. 40-ft 20 percent SEBACONITRILER on gas chrom. RA 42/60.<br />

3. 4-ft PORAPAKR N 8o/ioo.<br />

4. 6-ft molecular sieve bx 80/100.<br />

Stack gas samples were collected in 30 to 50 cc syringes via a<br />

tee on a long stainless steel probe, which can be inserted into the<br />

stack, at nine different locations, They were then transferred to a<br />

smaller 1 cm3 syringe via a small glass coup1 ing device sealed at both<br />

ends with a rubber grommet. The 1-cm3 samples were injected into a<br />

Varian 1700 chromatograph for hydrocarbon analysis. The chromatograph<br />

has a 1/8-in. x 6-ft column packed with 5A molecular sieves and a<br />

1/4-in. x 4-ft column packed with glass beads connected in series with<br />

a bypass before and after the molecular sieve column, control 1 ed by a<br />

need1.e valve to split the sample. The data are reported as ppm total<br />

HC, ppm methane, and ppm non-methane hydrocarbons (NMHC). The CO<br />

content in the stack was determined by using a Ki tagawa sampl ing<br />

probe.<br />

The o2 content in the stack was determined via a Teledyne<br />

02/combustible analyzer.<br />

3. Test Results. Petro-Tex has been involved in a modification<br />

plan for its '0x0' incinerator unit after startup. The facility was<br />

tested by the company after each major modification to determine the<br />

impact <strong>of</strong> these changes on the VOC destruction efficiency. The incinerator<br />

showed improved performance after each modification and the destruction<br />

efficiency increased <strong>from</strong> about 70 percent to above 99 percent, Table<br />

D-4 provides a summary <strong>of</strong> these test results. The modifications made<br />

in the incinerator are described below.<br />

November 1977<br />

Test data prior to these changes showed the incinerator was not<br />

destroying hydrocarbons as we1 1 as it should (VOC destruction efficiency<br />

as low as 70 percent), so the following changes were made:<br />

front;<br />

1. Moved the duct burner baffles <strong>from</strong> back <strong>of</strong> the burner to the