<strong>Levelflex</strong> M <strong>FMP40</strong> with HART/4...20 mA Mounting<br />

3.4.11 Turn housing<br />

After mounting, the housing can be turned 350° in order to simplify access to the display and the<br />

terminal compartment. Proceed as follows to turn the housing to the required position:<br />

• Undo the fixing screws (1)<br />

• Turn the housing (2) in the required direction<br />

• Tighten up the fixing screws (1).<br />

2<br />

1<br />

F12/F23 housing T12 housing<br />

3.5 Post-installation check<br />

allen key<br />

4 mm/0.1”<br />

L00-FMP4xxxx-17-00-00-en-028<br />

After the measuring instrument has been installed, perform the following checks:<br />

• Is the measuring instrument damaged (visual check)?<br />

• Does the measuring instrument correspond to the measuring point specifications such as process<br />

temperature/pressure, ambient temperature, measuring range, etc.?<br />

• Are the measuring point number and labeling correct (visual check)?<br />

• Is the measuring instrument adequately protected against rain and direct sunlight (see → ä 75)?<br />