<strong>Levelflex</strong> M <strong>FMP40</strong> with HART/4...20 mA Wiring<br />
4.3 Recommended connection<br />
4.3.1 Equipotential bonding<br />
Connect the Equipotential bonding to the external ground terminal (1) of the transmitter.<br />
1<br />
F12/F23 housing T12 housing<br />
L00-FMP4xxxx-17-00-00-en-032<br />
4.3.2 Wiring screened cable<br />
" Caution!<br />
In Ex applications, the instrument must only be grounded on the sensor side. Further safety<br />
instructions are given in the separate documentation for applications in explosion hazardous areas.<br />
4.4 Degree of protection<br />
• with closed housing tested according to<br />
– IP68, NEMA6P (24 h at 1.83 m under water surface)<br />
– IP66, NEMA4X<br />
• with open housing: IP20, NEMA1 (also ingress protection of the display)<br />
4.5 Post-connection check<br />
After wiring the measuring instrument, perform the following checks:<br />
• Is the terminal allocation correct (see → ä 36 and → ä 37)?<br />
• Is the cable gland tight?<br />
• Is the housing cover screwed tight?<br />
• If auxiliary power is available:<br />
Is the instrument ready for operation and is the liquid crystal display visible?<br />