<strong>Levelflex</strong> M <strong>FMP40</strong> with HART/4...20 mA Technical data<br />

Influence of ambiente<br />

temperature<br />

The measurements are carried out in accordance with EN 61298-3:<br />

• digital output:<br />

– <strong>FMP40</strong><br />

average TK : 0.6 mm/10 K, max. ±3.5 mm over the entire temperature range -40 °C...+80 °C<br />

2-wire:<br />

• Current output (additional error, in reference to the span of 16 mA):<br />

• Zero point (4 mA)<br />

average TK : 0.032 %/10 K, max. 0.35 % over the entire temperature range -40 °C...+80 °C<br />

• Span (20 mA)<br />

average TK : 0.05 %/10 K, max. 0.5 % over the entire temperature range -40 °C...+80 °C<br />

4-wire:<br />

• Current output (additional error, in reference to the span of 16 mA):<br />

• Zero point (4 mA)<br />

average TK : 0.02 %/10 K, max. 0.29 % over the entire temperature range -40 °C...+80 °C<br />

• Span (20 mA)<br />

average TK : 0.06 %/10 K, max. 0.89% over the entire temperature range -40 °C...+80 °C<br />

10.1.4 Operating conditions: Environment<br />

Ambient temperature range Ambient temperature for the transmitter: -40 °C ... +80 °C (-40 °F … +176 °F)<br />

The functionality of the LCD display may be limited for temperatures<br />

Ta+60 °C.<br />

A weather protection cover should be used for outdoor operation if the instrument is exposed to<br />

direct sunlight.<br />

Ambient temperature limits If temperatures above 80 °C are present at the process connection, the permitted ambient<br />

temperature is reduced according to the following diagram (temperature derating):<br />

max. ambient temperature<br />

T [°C]<br />

80<br />

-40<br />

-40 0 50<br />

Storage temperature -40 °C … +80 °C (-40 °F … +176°F)<br />

Climate class DIN EN 60068-2-38 (test Z/AD)<br />

60<br />

40<br />

0<br />

Vibration resistance DIN EN 60068-2-64 / IEC 68-2-64: 20…2000 Hz, 1 (m/s 2 ) 2 /Hz<br />

80 °C with separate<br />

housing<br />

75 °C with distance<br />

sleeve<br />

65 °C standard compact<br />

F12/T12 housing<br />

60 °C standard compact<br />

F23 housing<br />

80 100 150 T [°C]<br />

max. process connection temperature<br />

L00-<strong>FMP40</strong>xxx-05-00-00-en-001<br />