Levelflex M FMP40 - Process Centre Of Excellence.
Levelflex M FMP40 - Process Centre Of Excellence.
Levelflex M FMP40 - Process Centre Of Excellence.
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Levelflex</strong> M <strong>FMP40</strong> with HART/4...20 mA Technical data<br />
Influence of ambiente<br />
temperature<br />
The measurements are carried out in accordance with EN 61298-3:<br />
• digital output:<br />
– <strong>FMP40</strong><br />
average TK : 0.6 mm/10 K, max. ±3.5 mm over the entire temperature range -40 °C...+80 °C<br />
2-wire:<br />
• Current output (additional error, in reference to the span of 16 mA):<br />
• Zero point (4 mA)<br />
average TK : 0.032 %/10 K, max. 0.35 % over the entire temperature range -40 °C...+80 °C<br />
• Span (20 mA)<br />
average TK : 0.05 %/10 K, max. 0.5 % over the entire temperature range -40 °C...+80 °C<br />
4-wire:<br />
• Current output (additional error, in reference to the span of 16 mA):<br />
• Zero point (4 mA)<br />
average TK : 0.02 %/10 K, max. 0.29 % over the entire temperature range -40 °C...+80 °C<br />
• Span (20 mA)<br />
average TK : 0.06 %/10 K, max. 0.89% over the entire temperature range -40 °C...+80 °C<br />
10.1.4 Operating conditions: Environment<br />
Ambient temperature range Ambient temperature for the transmitter: -40 °C ... +80 °C (-40 °F … +176 °F)<br />
The functionality of the LCD display may be limited for temperatures<br />
Ta+60 °C.<br />
A weather protection cover should be used for outdoor operation if the instrument is exposed to<br />
direct sunlight.<br />
Ambient temperature limits If temperatures above 80 °C are present at the process connection, the permitted ambient<br />
temperature is reduced according to the following diagram (temperature derating):<br />
max. ambient temperature<br />
T [°C]<br />
80<br />
-40<br />
-40 0 50<br />
Storage temperature -40 °C … +80 °C (-40 °F … +176°F)<br />
Climate class DIN EN 60068-2-38 (test Z/AD)<br />
60<br />
40<br />
0<br />
Vibration resistance DIN EN 60068-2-64 / IEC 68-2-64: 20…2000 Hz, 1 (m/s 2 ) 2 /Hz<br />
80 °C with separate<br />
housing<br />
75 °C with distance<br />
sleeve<br />
65 °C standard compact<br />
F12/T12 housing<br />
60 °C standard compact<br />
F23 housing<br />
80 100 150 T [°C]<br />
max. process connection temperature<br />
L00-<strong>FMP40</strong>xxx-05-00-00-en-001<br />
Endress + Hauser 95