06.06.2013 Views

Levelflex M FMP40 - Process Centre Of Excellence.

Levelflex M FMP40 - Process Centre Of Excellence.

Levelflex M FMP40 - Process Centre Of Excellence.

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Levelflex</strong> M <strong>FMP40</strong> with HART/4...20 mA Commissioning<br />

ENDRESS + HAUSER<br />

–<br />

+<br />

ENDRESS + HAUSER<br />

–<br />

+<br />

E<br />

E<br />

⇒<br />

⇒<br />

After selection "length too short" or "length too long", the calculation of the new value need approx.<br />

10 s.<br />

Function "empty calibr." (005)<br />

This function is used to enter the distance from the flange (reference point of the measurement) to<br />

the minimum level (=zero).<br />

E<br />

Function "full calibr." (006)<br />

E = empty calibration (= zero)<br />

E max = probe length – lower blocking distance<br />

L00-FMP4xxxx-14-00-06-en-008<br />

This function is used to enter the distance from the minimum level to the maximum level (=span).<br />

F<br />

L00-FMP4xxxx-14-00-06-en-009<br />

Endress + Hauser 59<br />

0%<br />

100%<br />

0%<br />

F = full calibration (= span)<br />

F max = E – upper blocking distance