<strong>Levelflex</strong> M <strong>FMP40</strong> with HART/4...20 mA Wiring<br />
" Caution!<br />
Before connection please note the following:<br />
-<br />
-<br />
Wiring in T12 housing<br />
● The power supply must be identical to the data on the<br />
nameplate (1).<br />
● Switch off power supply before connecting up the device.<br />
1<br />
● Connect Equipotential bonding to transmitter<br />
ground terminal (7) before connecting up the device.<br />
● Tighten the locking screw (8):<br />
It forms the connection between the probe and the housing<br />
ground potential.<br />
When you use the measuring system in hazardous areas, make sure you comply with<br />
national standards and the specifications in the safety instructions (XA’s).<br />
Make sure you use the specific cable gland.<br />
Connect up the <strong>Levelflex</strong> M as follows:<br />
Before unscrew housing cover (2) at seperate connection room<br />
turn off the power supply!<br />
● Insert cable (3) through gland (4).<br />
A standard installation cable is sufficient if only the analogue signal is<br />
used. Use a screened cable when working with a superimposed<br />
communications signal (HART).<br />
Only ground screening of the line (5) on sensor side.<br />
●<br />
●<br />
●<br />
●<br />
Make connection (see pin assignment).<br />
Tighten cable gland (4). Max. torque 10...12 Nm!<br />
Screw on housing cover (2)<br />
(on dust-Ex torque ≈ 40 Nm).<br />
Switch on power supply.<br />
communication<br />
resistor<br />
(> 250 Ω)<br />
4...20 mA<br />
power<br />
1 2<br />
L- L+<br />
5<br />
3 4<br />
I+ I-<br />
2-wire-version<br />
alternatively<br />
Commubox<br />
FXA191/195<br />
DXR375<br />
test sockets for testing<br />
of the signal current<br />
plant<br />
ground<br />
ENDRESS+HAUSER<br />
LEVELFLEX-M<br />
Order Code:<br />
Made in Germany<br />
D-79689 Maulburg<br />
Ser.-No.:<br />
IP68 / NEMA 6P<br />
LN= PN=<br />
Profibus PA<br />
Foundation Fieldbus<br />
90 … 253 V AC 1VA<br />
10,5 … 32VDC 1W<br />
16 … 3 V DC 0,8W<br />
4 … 20 mA HART<br />
TA > 70°C : t >85°C<br />
2-wire<br />
4-wire<br />
if modification<br />
X=<br />
Patents<br />
see sep. label<br />
Dat./Insp.:<br />
D01301-A<br />
L00-<strong>FMP40</strong>xxx-04-00-00-en-002<br />
Endress + Hauser 37<br />
3<br />
4<br />
7<br />
8<br />
1 2 3 4<br />