VARI❋LITE® - <strong>VL2000</strong> WASH LUMINAIRE USER’S MANUAL<br />
PAN<br />
NO<br />
SENS<br />
PAN<br />
SENS<br />
ACTV<br />
SRCH/FOR/<br />
BRD1<br />
BRD2<br />
TILT<br />
ENCR<br />
FAIL<br />
Table A-1: Troubleshooting Gui<strong>de</strong> (Continued)<br />
Error Display Description Possible Cause and Remedy<br />
Enco<strong>de</strong>r faulty<br />
Replace pan end-of-travel/enco<strong>de</strong>r<br />
sensor assembly<br />
Pan Sensor Not Found EOT flag attached to large pulley is<br />
not engaging the EOT sensor<br />
- Ensure flag is attached to the<br />
large pulley<br />
- Ensure that flag passes through<br />
the sensor at a <strong>de</strong>pth sufficient<br />
to engage the sensor beam<br />
Pan belt disconnected, extremely<br />
loose or not installed properly<br />
- Properly install belt between pan<br />
motor and large pulley<br />
Pan Sensor Always Active Main board pan/tilt connector (J9)<br />
disconnected<br />
- Connect main board pan/tilt<br />
connector (J9)<br />
End-of-travel sensor connector (J2)<br />
disconnected<br />
- Connect end-of-travel sensor<br />
connector (J2)<br />
Searching for Board 1 or 2 Attmepting to communicate with<br />
Board 1 or Board 2. System will<br />
return either OK or an error co<strong>de</strong>.<br />
Tilt Enco<strong>de</strong>r Failure Main board pan/tilt connector (J9)<br />
disconnected<br />
- Connect main board pan/tilt<br />
connector (J9)<br />
Tilt motor disconnected<br />
- Connect tilt motor power<br />
Enco<strong>de</strong>r faulty<br />
Replace tilt end-of-travel/enco<strong>de</strong>r<br />
sensor assembly<br />
88 17-Sep-02 02.9671.0001 E