VARI❋LITE® - <strong>VL2000</strong> WASH LUMINAIRE USER’S MANUAL<br />
Self Tests<br />
Running Parameter Tests<br />
The luminaire is capable of running self tests by using the TEST menu functions. For<br />
complete <strong>de</strong>tails and values for each test refer to “Diagnostic Tests” on page 72.<br />
Note: After 10 seconds of inactivity, the menu display will change to the <strong>de</strong>fault state<br />
showing the address.<br />
When running tests on multiple luminaires, a loopback connector is required at the<br />
master luminaire (first in link) and a male termination connector is required at the last<br />
luminaire in the link. (Refer to page 14 for more information regarding the<br />
construction of these connectors.)<br />
Master luminaire containing<br />
software version to download<br />
Loopback Connector<br />
<strong>Luminaire</strong> 1<br />
requiring update<br />
Data Thru Data Thru<br />
<strong>Luminaire</strong> 2<br />
requiring update<br />
Termination Connector<br />
Move Disable<br />
The Move option has been ad<strong>de</strong>d to the test menu. This allows for pan/tilt functions<br />
to be disabled so that the luminaire can be placed in any position for testing without<br />
movement occurring. In or<strong>de</strong>r to regain full control of the luminaire, Move will need<br />
to be enabled after testing.<br />
Note: When setting the Move option to disable, luminaires linked by a loopback<br />
connector will have pan and tilt disabled for all the luminaires that are linked.<br />
70 17-Sep-02 02.9671.0001 E