Cues and Sequences<br />

Overview<br />

MENU SYSTEM : CUES AND SEQUENCES 4<br />

The luminaire has the ability to store and playback cues in<strong>de</strong>pen<strong>de</strong>nt of a console.<br />

Cues are stored as numbers from 1 to 99 by using the Cue (Cue Processing) functions<br />

available in the menu system. This also allows you to create your own test sequences<br />

to be played back on a group of luminaires.<br />

Refer to “Menu System Functions” on page 57 for a complete breakdown of Cue and<br />

Man (<strong>Manual</strong> Commands) functions.<br />

Storing<br />

The luminaire is able to store its current position into a cue; this information can be set<br />

via a console or by using the menu system Man (<strong>Manual</strong> Commands) function.<br />

Playback<br />

Cues can be joined into a sequence to be played back without a console. However,<br />

only one sequence can run at a time.<br />

A sequence can either replay the cues stored in each luminaire or replay the cues<br />

stored in a master luminaire. Playing a cue sequence for all luminaires in the data link<br />

is triggered by a “master” luminaire using the PSEQ (Play Sequence) command. The<br />

cue follow time (FLTM) is taken from the luminaire that is running the sequence (it is<br />

possible to view the follow time of each cue by playing the cue PCUE and then<br />

viewing the cue follow time FLTM). A playback sequence can be set to start<br />

automatically after power up by setting the Auto (AutoPlay) feature to ON.<br />

Note: Up to 32 luminaires can be linked together to run a sequence if they are data<br />

linked together. Refer to “Connecting Data and Power” on page 19.<br />

Hardware Requirements<br />

Data cables used in the multi-luminaire playback feature must have two twisted pairs<br />

and a shield. It is also recommen<strong>de</strong>d that cables meet all other USITT DMX<br />

specification requirements. Refer to “Data Cables” on page 12.<br />

Loopback and termination connectors are used in this process. Refer to page 14 for<br />

more information regarding the construction of these connectors.<br />