MENU SYSTEM : CUES AND SEQUENCES 4<br />
Choose Sequence Mo<strong>de</strong>:<br />
MSEQ will replay the cues from the master luminaire.<br />
ISEQ will play the cues from each individual luminaire, if any. In ISEQ, if the<br />
number of cues is different, it will only play as many as each luminaire has stored.<br />
The follow time is taken from the master luminaire.<br />
Step 1. Press [Menu].<br />
Step 2. Press [Up] / [Down] arrows until Cue appears. Press [Enter].<br />
Step 3. Press [Up] / [Down] arrows until SEQ appears. Press [Enter].<br />
Step 4. Press [Up] / [Down] arrows to toggle between ISEQ and MSEQ. Press<br />
[Enter] to select mo<strong>de</strong>.<br />
To make a sequence AutoPlay at power up:<br />
Step 1. Press [Menu].<br />
Step 2. Press [Up] / [Down] arrows until Cue appears. Press [Enter].<br />
Step 3. Press [Up] / [Down] arrows until Auto appears. Press [Enter].<br />
Step 4. Use [Up] / [Down] arrows to toggle between OFF (the <strong>de</strong>fault) and ON.<br />
Press [Enter] to select the mo<strong>de</strong>.<br />
To store cues from a console:<br />
Step 1. Clear memory by <strong>de</strong>leting cues or sequence, if required.<br />
Step 2. Recall cue at the console.<br />
Step 3. From Cue menu, set FLTM, then at Stor store cue. If each luminaire has<br />
separate data then store each cue into each luminaire. The sequence mo<strong>de</strong> to<br />
use in this case would be ISEQ.<br />
02.9671.0001 E 17-Sep-02 69