ATT 2 – NETWORK ELEMENTS AND OTHER SERVICES/AT&T-9STATE<br />

PAGE 19 OF 44<br />

<strong>Southern</strong> <strong>Light</strong><br />

1Q08 GENERIC INTERCONNECTION AGREEMENT – 03/10/08<br />

which provides for simultaneous two-way transmission of serial bipolar return-to-zero synchronous<br />

digital electrical signals at a transmission rate of fifty-one point eighty-four (51.84) Mbps. It may<br />

provide transport for twenty-eight (28) DS1 channels, each of which provides the digital equivalent<br />

of twenty-four (24) analog voice grade channels. The interface to unbundled dedicated STS-1<br />

transport is a metallic-based electrical interface.<br />

2.3.10 Both DS3 Loop and STS-1 Loop require a SI in order to ascertain availability.<br />

2.3.11 DS3 services come with a test point and a DLR. Mileage is airline miles, rounded up and a<br />

minimum of one (1) mile applies. AT&T’s <strong>Light</strong>Gate® TR73501 Service Interface and Performance<br />

Specifications, Issue D, June 1995 applies to DS3 services.<br />

2.3.12 <strong>Southern</strong> <strong>Light</strong> may obtain a maximum of a single Unbundled DS3 Loop to any single building in<br />

which DS3 Loops are available as Unbundled Loops.<br />

2.4 Unbundled Copper Loops (UCL).<br />

2.4.1 AT&T shall make available UCLs. The UCL is a copper twisted pair Loop that is unencumbered by<br />

any intervening equipment (e.g., filters, load coils, range extenders, digital loop carrier, or<br />

repeaters) and is not intended to support any particular telecommunications service. The UCL will<br />

be offered in two (2) types – Designed and Non-Designed.<br />

2.4.2 Unbundled Copper Loop – Designed (UCL-D)<br />

2.4.2.1 The UCL-D will be provisioned as a dry copper twisted pair (2-wire or 4-wire) Loop that is<br />

unencumbered by any intervening equipment (e.g., filters, load coils, range extenders, digital loop<br />

carrier, or repeaters).<br />

2.4.2.2 A UCL-D will be eighteen thousand (18,000) feet or less in length and is provisioned according to<br />

Resistance Design parameters, may have up to six thousand (6,000) feet of bridged tap and will<br />

have up to thirteen hundred (1300) Ohms of resistance.<br />

2.4.2.3 The UCL-D is a designed circuit, is provisioned with a test point, and comes standard with a DLR.<br />

OC is a chargeable option for a UCL-D; however, OC is always required on UCLs where a reuse of<br />

existing facilities has been requested by <strong>Southern</strong> <strong>Light</strong>.<br />

2.4.2.4 These Loops are not intended to support any particular services and may be utilized by <strong>Southern</strong><br />

<strong>Light</strong> to provide a wide-range of telecommunications services as long as those services do not<br />

adversely affect AT&T’s network. This facility will include a Network Interface Device (NID) at the<br />

customer’s location for the purpose of connecting the Loop to the customer’s inside wire.<br />

2.4.3 Unbundled Copper Loop – Non-Designed (UCL-ND)<br />

2.4.3.1 The UCL–ND is provisioned as a dedicated 2-wire metallic transmission facility from AT&T’s Main<br />

Distribution Frame (MDF) to a customer’s premises (including the NID). The UCL-ND will be a “dry<br />

copper” facility in that it will not have any intervening equipment such as load coils, repeaters, or<br />

digital access main lines (DAMLs), and may have up to six thousand (6,000) feet of bridged tap<br />

CCCS 68 of 370