12 12 - - TROUBLESHOOTING<br />

TROUBLESHOOTING<br />

GUIDE GUIDE FOR FOR THE<br />

THE<br />

MOST MOST COMMON<br />

COMMON<br />

FAILURES FAILURES OR<br />

OR<br />

ERRORS<br />

ERRORS<br />

In SERVICE mode, failures or faults, when<br />

present are immediately displayed in the<br />

following way (see Key 1 features):<br />

E01 - CUP<br />

E02 - GRINDER<br />

E03 - GROUP<br />

Display message Possible cause<br />

E04 - ESPRESSO PUMP<br />

- cup missing<br />

- cup microswitch detector failure<br />

- coffee missing<br />

- grinder blocked<br />

- group motor failure<br />

- motor position microswitch failure<br />

- pump failure<br />

- coffee solenoid valve<br />

- volumetric counter<br />

E05 - INSTANT PRODUCT PUMP - pump failure<br />

- coffee/instant product failure<br />

English<br />

E07 - SCALE FACTOR - error in scale factor setting (basic coin) in<br />

the coiner<br />

E08 - WATER EMPTY - water missing<br />

- liquid waste bin full<br />

- tray microswitch failure<br />

E09 - EEPROM<br />

E11 - NTCPROBE<br />

E12 - TCAF