12 12 - - TROUBLESHOOTING<br />
TROUBLESHOOTING<br />
GUIDE GUIDE FOR FOR THE<br />
THE<br />
MOST MOST COMMON<br />
COMMON<br />
FAILURES FAILURES OR<br />
OR<br />
ERRORS<br />
ERRORS<br />
In SERVICE mode, failures or faults, when<br />
present are immediately displayed in the<br />
following way (see Key 1 features):<br />
E01 - CUP<br />
E02 - GRINDER<br />
E03 - GROUP<br />
Display message Possible cause<br />
E04 - ESPRESSO PUMP<br />
- cup missing<br />
- cup microswitch detector failure<br />
- coffee missing<br />
- grinder blocked<br />
- group motor failure<br />
- motor position microswitch failure<br />
- pump failure<br />
- coffee solenoid valve<br />
- volumetric counter<br />
E05 - INSTANT PRODUCT PUMP - pump failure<br />
- coffee/instant product failure<br />
English<br />
E07 - SCALE FACTOR - error in scale factor setting (basic coin) in<br />
the coiner<br />
E08 - WATER EMPTY - water missing<br />
- liquid waste bin full<br />
- tray microswitch failure<br />
E09 - EEPROM<br />
E11 - NTCPROBE<br />
E12 - TCAF