Serial terminal<br />
Technical Information<br />
The serial connector which is on the connector panel of the projector conforms to the RS-232C interface<br />
specification, so that the projector can be controlled by a personal computer which is connected to this connecter.<br />
Connection<br />
COMPUTER1<br />
Pin assignments and signal names<br />
Communication settings<br />
Basic format<br />
D-sub 9 pin (male)<br />
Pin No. Signal name Contents<br />
A NC<br />
B TXD Transmitted data<br />
C RXD Received data<br />
D NC<br />
E GND Earth<br />
F NC<br />
G<br />
H<br />
RTS<br />
CTS<br />
Connected internally<br />
I NC<br />
Signal level RS-232C Character length 8bits<br />
Sync. method Asynchronous Stop bit 1bit<br />
Baud rate 9600bps X parameter None<br />
Parity None S parameter None<br />
STX Command : Parameter ETX<br />
Start byte<br />
(02h)<br />
1byte End<br />
3bytes 1byte -<br />
(03h)<br />
4bytes<br />
Serial terminal (male)<br />
The data streaming from the computer will<br />
start with STX, and proceed to Command,<br />
Parameter and end with ETX. You can<br />
add the required parameter.<br />
The projector can not receive any command for 10 seconds after the lamp is switched on. Wait 10 seconds<br />
before sending the command.<br />
If sending multiple commands, check that a response has been received from the projector for one<br />
command before sending the next command.<br />
When a command which does not require parameters to be sent, the colon (:) is not required.<br />
If an incorrect command is sent from the personal computer, the ER401 command will be sent from the<br />
projector to the personal computer.<br />
ENGLISH - 47<br />
Appendix